Re: [PATCH 2/2] iio: potentiometer: Add driver support for AD5110
From: Jonathan Cameron
Date: Sun Aug 08 2021 - 12:20:15 EST
On Sat, 7 Aug 2021 23:04:18 +0530
Mugilraj Dhavachelvan <dmugil2000@xxxxxxxxx> wrote:
> Sorry some formatting issues happened in my previous mail.
>
> On 07/08/21 10:56 pm, Mugilraj Dhavachelvan wrote:
> >
> >
> > On 07/08/21 5:41 pm, Lars-Peter Clausen wrote:
> >> On 8/7/21 7:08 AM, Mugilraj Dhavachelvan wrote:
> >>> The AD5110/AD5112/AD5114 provide a nonvolatile solution
> >>> for 128-/64-/32-position adjustment applications, offering
> >>> guaranteed low resistor tolerance errors of ±8% and up to
> >>> ±6 mA current density.
> >>>
> >>> Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/AD5110_5112_5114.pdf
> >>> Signed-off-by: Mugilraj Dhavachelvan <dmugil2000@xxxxxxxxx>
> >>
> >> Thanks for the patch. This looks really good>
> >>
>
...
> >>> +
> >>> +static IIO_DEVICE_ATTR(wiper_pos_eeprom, 0644,
> >>> + ad5110_eeprom_read,
> >>> + ad5110_eeprom_write, 0);
> >> This is new custom ABI and needs to be documented
We have existing similar ABI in dac/mcp4725 which is simply
called store_eeprom
It's in the main docs
Documentation/ABI/testing/sysfs-bus-iio as storing
device configuration. I'm guessing this device doesn't have
other configuration so that description will work?
>
> > I'm not aware of this, fixed in v2.
> >>> +static int ad5110_write_raw(struct iio_dev *indio_dev,
> >>> + struct iio_chan_spec const *chan,
> >>> + int val, int val2, long mask)
> >>> +{
> >>> + struct ad5110_data *data = iio_priv(indio_dev);
> >>> + int ret;
> >>> +
> >>> + switch (mask) {
> >>> + case IIO_CHAN_INFO_RAW:
> >>> + if (val >= data->cfg->max_pos || val < 0)
> >> val == data->cfg->max_pos is a valid setting. Writing max_pos puts it in top-scale mode which gives maximum resistance.
> > Fixed in v2.
> >>> + return -EINVAL;
> >>> +
> >>> + return ad5110_write(data, AD5110_RDAC_WR, val << data->cfg->shift);
> >>> + case IIO_CHAN_INFO_ENABLE:
> >>> + if (val < 0 || val > 1)
> >>> + return -EINVAL;
> >>> + if (data->enable == val)
> >>> + return 0;
> >>> + ret = ad5110_write(data, AD5110_SHUTDOWN, val);
> >> Doesn't val have to be inverted to get the right behavior
>
> > I just replicated the datasheet operation.
> > You mean,
> > 1 - shutdown off
> > 0 - shutdown on
> > If yes, then the user won't get confused with the datasheet and the behavior of the driver?
> > Or Is it work like this? But yeah even I like this change it's more convenient.
ABI has to be consistent and writing an enable attribute with 1 has to mean enabling it whatever
approach the datasheet takes to describe things. Most users don't read
datasheets so interface needs to be intuitive.
> >>> + if (ret)
> >>> + return ret;
> >>> + data->enable = val;
> >>> + return 0;
> >>> + default:
> >>> + return -EINVAL;
> >>> + }
> >>> +}
> >> [...]
> > Thanks for feedback!!
> >