Re: [PATCH net v2 1/2] ptp: idt82p33: optimize idt82p33_adjtime

From: Andrew Lunn
Date: Fri Sep 17 2021 - 15:58:36 EST


On Fri, Sep 17, 2021 at 10:39:48AM -0400, min.li.xe@xxxxxxxxxxx wrote:
> From: Min Li <min.li.xe@xxxxxxxxxxx>
>
> The current adjtime implementation is read-modify-write and immediately
> triggered, which is not accurate due to slow i2c bus access. Therefore,
> we will use internally generated 1 PPS pulse as trigger, which will
> improve adjtime accuracy significantly. On the other hand, the new trigger
> will not change TOD immediately but delay it to the next 1 PPS pulse.
>
> Signed-off-by: Min Li <min.li.xe@xxxxxxxxxxx>
> ---
> drivers/ptp/ptp_idt82p33.c | 221 ++++++++++++++++++++++++++++++---------------
> drivers/ptp/ptp_idt82p33.h | 28 +++---
> 2 files changed, 165 insertions(+), 84 deletions(-)
>
> diff --git a/drivers/ptp/ptp_idt82p33.c b/drivers/ptp/ptp_idt82p33.c
> index c1c959f..abe628c 100644
> --- a/drivers/ptp/ptp_idt82p33.c
> +++ b/drivers/ptp/ptp_idt82p33.c
> @@ -24,15 +24,10 @@ MODULE_LICENSE("GPL");
> MODULE_FIRMWARE(FW_FILENAME);
>
> /* Module Parameters */
> -static u32 sync_tod_timeout = SYNC_TOD_TIMEOUT_SEC;
> -module_param(sync_tod_timeout, uint, 0);
> -MODULE_PARM_DESC(sync_tod_timeout,
> -"duration in second to keep SYNC_TOD on (set to 0 to keep it always on)");
> -

Despite module parameters not being liked, they are probably also
considered ABI. So you probably cannot remove it.

Andrew