Re: [RFC PATCH] memory: renesas-rpc-if: Correct QSPI data transfer in Manual mode

From: Krzysztof Kozlowski
Date: Tue Sep 28 2021 - 06:36:02 EST


On Wed, 22 Sep 2021 11:10:06 +0200, Wolfram Sang wrote:
> This patch fixes 2 problems:
> [1] The output warning logs and data loss when performing
> mount/umount then remount the device with jffs2 format.
> [2] The access width of SMWDR[0:1]/SMRDR[0:1] register is wrong.
>
> This is the sample warning logs when performing mount/umount then
> remount the device with jffs2 format:
> jffs2: jffs2_scan_inode_node(): CRC failed on node at 0x031c51d4:
> Read 0x00034e00, calculated 0xadb272a7
>
> [...]

Applied, thanks!

[1/1] memory: renesas-rpc-if: Correct QSPI data transfer in Manual mode
commit: fff53a551db50f5edecaa0b29a64056ab8d2bbca

Best regards,
--
Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxxxxx>