[PATCH 2/6] input: ti_am335x_tsc: fix STEPCONFIG setup for Z2
From: Dario Binacchi
Date: Sun Oct 24 2021 - 11:09:33 EST
The Z2 step configuration doesn't erase the SEL_INP_SWC_3_0 bit-field
before setting the ADC channel. This way its value could be corrupted by
the ADC channel selected for the Z1 coordinate.
Fixes: 8c896308fea ("input: ti_am335x_adc: use only FIFO0 and clean up a little")
Signed-off-by: Dario Binacchi <dariobin@xxxxxxxxx>
---
drivers/input/touchscreen/ti_am335x_tsc.c | 5 ++++-
1 file changed, 4 insertions(+), 1 deletion(-)
diff --git a/drivers/input/touchscreen/ti_am335x_tsc.c b/drivers/input/touchscreen/ti_am335x_tsc.c
index fd3ffdd23470..cfc943423241 100644
--- a/drivers/input/touchscreen/ti_am335x_tsc.c
+++ b/drivers/input/touchscreen/ti_am335x_tsc.c
@@ -196,7 +196,10 @@ static void titsc_step_config(struct titsc *ts_dev)
STEPCONFIG_OPENDLY);
end_step++;
- config |= STEPCONFIG_INP(ts_dev->inp_yn);
+ config = STEPCONFIG_MODE_HWSYNC |
+ STEPCONFIG_AVG_16 | ts_dev->bit_yp |
+ ts_dev->bit_xn | STEPCONFIG_INM_ADCREFM |
+ STEPCONFIG_INP(ts_dev->inp_yn);
titsc_writel(ts_dev, REG_STEPCONFIG(end_step), config);
titsc_writel(ts_dev, REG_STEPDELAY(end_step),
STEPCONFIG_OPENDLY);
--
2.17.1