[PATCH v14 04/39] dt-bindings: clock: tegra-car: Document new clock sub-nodes

From: Dmitry Osipenko
Date: Mon Oct 25 2021 - 18:46:06 EST


Document sub-nodes which describe Tegra SoC clocks that require a higher
voltage of the core power domain in order to operate properly on a higher
clock rates. Each node contains a phandle to OPP table and power domain.

The root PLLs and system clocks don't have any specific device dedicated
to them, clock controller is in charge of managing power for them.

Reviewed-by: Rob Herring <robh@xxxxxxxxxx>
Signed-off-by: Dmitry Osipenko <digetx@xxxxxxxxx>
---
.../bindings/clock/nvidia,tegra20-car.yaml | 37 +++++++++++++++++++
1 file changed, 37 insertions(+)

diff --git a/Documentation/devicetree/bindings/clock/nvidia,tegra20-car.yaml b/Documentation/devicetree/bindings/clock/nvidia,tegra20-car.yaml
index 459d2a525393..f832abb7f11a 100644
--- a/Documentation/devicetree/bindings/clock/nvidia,tegra20-car.yaml
+++ b/Documentation/devicetree/bindings/clock/nvidia,tegra20-car.yaml
@@ -42,6 +42,36 @@ properties:
"#reset-cells":
const: 1

+patternProperties:
+ "^(sclk)|(pll-[cem])$":
+ type: object
+ properties:
+ compatible:
+ enum:
+ - nvidia,tegra20-sclk
+ - nvidia,tegra30-sclk
+ - nvidia,tegra30-pllc
+ - nvidia,tegra30-plle
+ - nvidia,tegra30-pllm
+
+ operating-points-v2: true
+
+ clocks:
+ items:
+ - description: node's clock
+
+ power-domains:
+ maxItems: 1
+ description: phandle to the core SoC power domain
+
+ required:
+ - compatible
+ - operating-points-v2
+ - clocks
+ - power-domains
+
+ additionalProperties: false
+
required:
- compatible
- reg
@@ -59,6 +89,13 @@ examples:
reg = <0x60006000 0x1000>;
#clock-cells = <1>;
#reset-cells = <1>;
+
+ sclk {
+ compatible = "nvidia,tegra20-sclk";
+ operating-points-v2 = <&opp_table>;
+ clocks = <&tegra_car TEGRA20_CLK_SCLK>;
+ power-domains = <&domain>;
+ };
};

usb-controller@c5004000 {
--
2.33.1