[PATCH 5.10 216/575] net: phy: micrel: make *-skew-ps check more lenient
From: Greg Kroah-Hartman
Date: Mon Nov 15 2021 - 14:40:43 EST
From: Matthias Schiffer <matthias.schiffer@xxxxxxxxxxxxxxx>
[ Upstream commit 67ca5159dbe2edb5dae7544447b8677d2596933a ]
It seems reasonable to fine-tune only some of the skew values when using
one of the rgmii-*id PHY modes, and even when all skew values are
specified, using the correct ID PHY mode makes sense for documentation
purposes. Such a configuration also appears in the binding docs in
Documentation/devicetree/bindings/net/micrel-ksz90x1.txt, so the driver
should not warn about it.
Signed-off-by: Matthias Schiffer <matthias.schiffer@xxxxxxxxxxxxxxx>
Link: https://lore.kernel.org/r/20211012103402.21438-1-matthias.schiffer@xxxxxxxxxxxxxxx
Signed-off-by: Jakub Kicinski <kuba@xxxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/net/phy/micrel.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)
diff --git a/drivers/net/phy/micrel.c b/drivers/net/phy/micrel.c
index 69b20a466c61c..b341a8be09f92 100644
--- a/drivers/net/phy/micrel.c
+++ b/drivers/net/phy/micrel.c
@@ -732,9 +732,9 @@ static int ksz9031_config_init(struct phy_device *phydev)
MII_KSZ9031RN_TX_DATA_PAD_SKEW, 4,
tx_data_skews, 4, &update);
- if (update && phydev->interface != PHY_INTERFACE_MODE_RGMII)
+ if (update && !phy_interface_is_rgmii(phydev))
phydev_warn(phydev,
- "*-skew-ps values should be used only with phy-mode = \"rgmii\"\n");
+ "*-skew-ps values should be used only with RGMII PHY modes\n");
/* Silicon Errata Sheet (DS80000691D or DS80000692D):
* When the device links in the 1000BASE-T slave mode only,
--
2.33.0