Re: [PATCH v2 1/2] bus: imx-weim: optionally enable continuous burst clock

From: Fabio Estevam
Date: Sat Dec 11 2021 - 06:04:15 EST


On Wed, Nov 24, 2021 at 3:10 PM Ivan Bornyakov <i.bornyakov@xxxxxxxxxxx> wrote:
>
> To enable continuous burst clock, add "fsl,continuous-burst-clk" along
> with "fsl,burst-clk-enable" property to the weim bus's devicetree node.
>
> Example:
> weim: weim@21b8000 {
> compatible = "fsl,imx6ul-weim", "fsl,imx6q-weim";
> reg = <0x021b8000 0x4000>;
> clocks = <&clks 143>;
> #address-cells = <2>;
> #size-cells = <1>;
> ranges = <0 0 0x50000000 0x08000000>;
> fsl,weim-cs-gpr = <&gpr>;
> fsl,burst-clk-enable;
> fsl,continuous-burst-clk;
>
> client-device@0 {
> ...
> };
> };
>
> Signed-off-by: Ivan Bornyakov <i.bornyakov@xxxxxxxxxxx>

Reviewed-by: Fabio Estevam <festevam@xxxxxxxxx>