[PATCH 5/8] scsi: hisi_sas: Prevent parallel controller reset and control phy command

From: John Garry
Date: Wed Dec 15 2021 - 09:43:32 EST


From: Qi Liu <liuqi115@xxxxxxxxxx>

A user may issue a control phy command from sysfs at any time, even if the
controller is resetting.

If a phy is disabled by hardreset/linkreset command before calling
get_phys_state() in the reset path, the saved phy state may be incorrect.

To avoid incorrectly recording the phy state, use hisi_hba.sem to ensure
that the controller reset may not run at the same time as when the phy
control function is running.

Signed-off-by: Qi Liu <liuqi115@xxxxxxxxxx>
Signed-off-by: John Garry <john.garry@xxxxxxxxxx>
---
drivers/scsi/hisi_sas/hisi_sas_main.c | 2 ++
1 file changed, 2 insertions(+)

diff --git a/drivers/scsi/hisi_sas/hisi_sas_main.c b/drivers/scsi/hisi_sas/hisi_sas_main.c
index 8df1fd680eac..977911580d8f 100644
--- a/drivers/scsi/hisi_sas/hisi_sas_main.c
+++ b/drivers/scsi/hisi_sas/hisi_sas_main.c
@@ -1148,6 +1148,7 @@ static int hisi_sas_control_phy(struct asd_sas_phy *sas_phy, enum phy_func func,
u8 sts = phy->phy_attached;
int ret = 0;

+ down(&hisi_hba->sem);
phy->reset_completion = &completion;

switch (func) {
@@ -1191,6 +1192,7 @@ static int hisi_sas_control_phy(struct asd_sas_phy *sas_phy, enum phy_func func,
out:
phy->reset_completion = NULL;

+ up(&hisi_hba->sem);
return ret;
}

--
2.26.2