[PATCH 4.19 194/239] power: bq25890: Enable continuous conversion for ADC at charging

From: Greg Kroah-Hartman
Date: Mon Jan 24 2022 - 14:31:34 EST


From: Yauhen Kharuzhy <jekhor@xxxxxxxxx>

[ Upstream commit 80211be1b9dec04cc2805d3d81e2091ecac289a1 ]

Instead of one shot run of ADC at beginning of charging, run continuous
conversion to ensure that all charging-related values are monitored
properly (input voltage, input current, themperature etc.).

Signed-off-by: Yauhen Kharuzhy <jekhor@xxxxxxxxx>
Reviewed-by: Hans de Goede <hdegoede@xxxxxxxxxx>
Signed-off-by: Sebastian Reichel <sebastian.reichel@xxxxxxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/power/supply/bq25890_charger.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/power/supply/bq25890_charger.c b/drivers/power/supply/bq25890_charger.c
index 8e2c41ded171c..e90253b3f6561 100644
--- a/drivers/power/supply/bq25890_charger.c
+++ b/drivers/power/supply/bq25890_charger.c
@@ -521,12 +521,12 @@ static void bq25890_handle_state_change(struct bq25890_device *bq,

if (!new_state->online) { /* power removed */
/* disable ADC */
- ret = bq25890_field_write(bq, F_CONV_START, 0);
+ ret = bq25890_field_write(bq, F_CONV_RATE, 0);
if (ret < 0)
goto error;
} else if (!old_state.online) { /* power inserted */
/* enable ADC, to have control of charge current/voltage */
- ret = bq25890_field_write(bq, F_CONV_START, 1);
+ ret = bq25890_field_write(bq, F_CONV_RATE, 1);
if (ret < 0)
goto error;
}
--
2.34.1