[PATCH v6 1/2] hwmon: (adm1275) Allow setting sample averaging
From: Potin Lai
Date: Wed Mar 02 2022 - 07:41:38 EST
Current driver assume PWR_AVG and VI_AVG as 1 by default, and user needs
to set sample averaging via sysfs manually.
This patch parses the properties "adi,power-sample-average" and
"adi,volt-curr-sample-average" from device tree, and setting sample
averaging during probe. Input value must be one of value in the
list [1, 2, 4, 8, 16, 32, 64, 128].
Signed-off-by: Potin Lai <potin.lai@xxxxxxxxxxxx>
---
drivers/hwmon/pmbus/adm1275.c | 40 ++++++++++++++++++++++++++++++++++-
1 file changed, 39 insertions(+), 1 deletion(-)
diff --git a/drivers/hwmon/pmbus/adm1275.c b/drivers/hwmon/pmbus/adm1275.c
index d311e0557401..3b07bfb43e93 100644
--- a/drivers/hwmon/pmbus/adm1275.c
+++ b/drivers/hwmon/pmbus/adm1275.c
@@ -475,6 +475,7 @@ static int adm1275_probe(struct i2c_client *client)
int vindex = -1, voindex = -1, cindex = -1, pindex = -1;
int tindex = -1;
u32 shunt;
+ u32 avg;
if (!i2c_check_functionality(client->adapter,
I2C_FUNC_SMBUS_READ_BYTE_DATA
@@ -687,7 +688,7 @@ static int adm1275_probe(struct i2c_client *client)
if ((config & (ADM1278_VOUT_EN | ADM1278_TEMP1_EN)) !=
(ADM1278_VOUT_EN | ADM1278_TEMP1_EN)) {
config |= ADM1278_VOUT_EN | ADM1278_TEMP1_EN;
- ret = i2c_smbus_write_byte_data(client,
+ ret = i2c_smbus_write_word_data(client,
ADM1275_PMON_CONFIG,
config);
if (ret < 0) {
@@ -756,6 +757,43 @@ static int adm1275_probe(struct i2c_client *client)
return -ENODEV;
}
+ if (data->have_power_sampling &&
+ of_property_read_u32(client->dev.of_node,
+ "adi,power-sample-average", &avg) == 0) {
+ if (!avg || avg > ADM1275_SAMPLES_AVG_MAX ||
+ BIT(__fls(avg)) != avg) {
+ dev_err(&client->dev,
+ "Invalid number of power samples");
+ return -EINVAL;
+ }
+ ret = adm1275_write_pmon_config(data, client, true,
+ ilog2(avg));
+ if (ret < 0) {
+ dev_err(&client->dev,
+ "Setting power sample averaging failed with error %d",
+ ret);
+ return ret;
+ }
+ }
+
+ if (of_property_read_u32(client->dev.of_node,
+ "adi,volt-curr-sample-average", &avg) == 0) {
+ if (!avg || avg > ADM1275_SAMPLES_AVG_MAX ||
+ BIT(__fls(avg)) != avg) {
+ dev_err(&client->dev,
+ "Invalid number of voltage/current samples");
+ return -EINVAL;
+ }
+ ret = adm1275_write_pmon_config(data, client, false,
+ ilog2(avg));
+ if (ret < 0) {
+ dev_err(&client->dev,
+ "Setting voltage and current sample averaging failed with error %d",
+ ret);
+ return ret;
+ }
+ }
+
if (voindex < 0)
voindex = vindex;
if (vindex >= 0) {
--
2.17.1