Re: [PATCH 2/6] dt-bindings: regulator: Add reg-external-output binding

From: Zev Weiss
Date: Wed May 04 2022 - 16:34:06 EST


On Wed, May 04, 2022 at 05:55:53AM PDT, Mark Brown wrote:
On Tue, May 03, 2022 at 11:52:48PM -0700, Zev Weiss wrote:
This describes an external output supplied by a regulator, such as a
power outlet on a power distribution unit (PDU).

OK, so this is that represnetation of the connection - which raises the
question about why the regulator needs a property?

+description: |
+ This describes an external output supplied by a regulator, such as
+ a power outlet on a power distribution unit (PDU).
+
+properties:
+ compatible:
+ const: reg-external-output
+
+ vout-supply:
+ description:
+ Phandle of the regulator supplying the output, which should have
+ the regulator-external-output property.
+
+required:

I think at a minimum anything like this would need some sort of
representation of how the output physically appears so that people can
work out how outputs are mapped to the hardware they see.

I don't quite understand what you're describing here -- could you elaborate on what you mean by "how the output physically appears", and what that might look like in a DT binding?

However we
already have a subsystem for external connectors - extcon. Perhaps this
should be a regulator client in the extcon API? It's common for
connectors to include some sort of power provision so it seems like this
would fit right in.

Interesting -- I wasn't previously aware of the extcon subsystem, thanks for the pointer. However, after looking at it a bit, I'm not sure I see how it'd be applicable here, since it looks like it's built to handle hardware that's at least sophisticated enough for software to tell whether or not something's plugged in, which isn't the case here. The connector is just a ground pin and +12VDC pin, no presence-detection mechanism or anything else. Outside of the regulator itself there's really no "device" there for software to talk to or otherwise interact with at all.


Thanks,