Re: [PATCH v2] soundwire: qcom: adjust autoenumeration timeout

From: Vinod Koul
Date: Mon May 09 2022 - 02:38:48 EST


On 06-05-22, 09:47, Srinivas Kandagatla wrote:
> Currently timeout for autoenumeration during probe and bus reset is set to
> 2 secs which is really a big value. This can have an adverse effect on
> boot time if the slave device is not ready/reset.
> This was the case with wcd938x which was not reset yet but we spent 2
> secs waiting in the soundwire controller probe. Reduce this time to
> 1/10 of Hz which should be good enough time to finish autoenumeration
> if any slaves are available on the bus.

Applied, thanks

--
~Vinod