Re: [PATCHv2 4/6] thermal: exynos: fixed the efuse min/max value for exynos5422

From: Krzysztof Kozlowski
Date: Sun May 15 2022 - 05:45:48 EST


On 15/05/2022 08:41, Anand Moon wrote:
> As per Exynos5422 user manaul e-Fuse range min~max range is 16~76.
> if e-Fuse value is out of this range, then thermal sensor may not
> sense thermal data properly.
>
> Cc: Bartlomiej Zolnierkiewicz <bzolnier@xxxxxxxxx>
> Signed-off-by: Anand Moon <linux.amoon@xxxxxxxxx>


Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>


Best regards,
Krzysztof