Re: [PATCHv2 1/2] i2c: designware: introduce a custom scl recovery for SoCFPGA platforms

From: Dinh Nguyen
Date: Wed Jun 01 2022 - 09:48:17 EST




On 5/24/22 11:43, Andy Shevchenko wrote:
On Tue, May 24, 2022 at 08:54:40AM -0500, Dinh Nguyen wrote:
The I2C pins on the SoCFPGA platforms do not go through a GPIO module,
thus cannot be recovered by the default method of by doing a GPIO access.
Only a reset of the I2C IP block can a recovery be successful.

Better now, but see my additional comments.

...

+ switch (dev->flags & MODEL_MASK) {
+ case MODEL_SOCFPGA:
+ rinfo->recover_bus = i2c_socfpga_scl_recovery;
+ break;
+ default:
+ rinfo->recover_bus = i2c_generic_scl_recovery;
+ break;
+ }

+ adap->bus_recovery_info = rinfo;

Usually we do not assign the pointer while data structure is incomplete.
That's said, please leave this line as it was.

On top of that, why you can't move the above switch to the place where old
function was assigned?


The reason is the assignment of the recover_bus needs to get done before the call to devm_gpiod_get_optional(), otherwise, the assignment is not taking place because of an error after returning from devm_gpiod_get_optional().

Dinh