Re: [PATCH v7 4/6] serial: take termios_rwsem for .rs485_config() & pass termios as param
From: Ilpo Järvinen
Date: Thu Jun 16 2022 - 01:15:44 EST
On Wed, 15 Jun 2022, Andy Shevchenko wrote:
> On Wed, Jun 15, 2022 at 03:48:27PM +0300, Ilpo Järvinen wrote:
> > To be able to alter ADDRB within .rs485_config(), take termios_rwsem
> > before calling .rs485_config() and pass termios.
>
> I would use ->rs485_config() as a reference to the callback.
>
> ...
>
> > - ret = port->rs485_config(port, rs485);
> > + ret = port->rs485_config(port, rs485, NULL);
>
> > +
>
> Stray change?
Yes it was.
> > if (ret)
> > memset(rs485, 0, sizeof(*rs485));
>
> ...
>
> > void (*handle_break)(struct uart_port *);
> > int (*rs485_config)(struct uart_port *,
> > - struct serial_rs485 *rs485);
> > + struct serial_rs485 *rs485,
> > + struct ktermios *termios);
>
> Dunno if termios has to be second parameter. The idea is to pass input data
> followed by (auxiliary) output as usual pattern.
I guess I can make termios 2nd param.
--
i.