[PATCH V10 1/3] dt-bindings: rtc: zynqmp: Add clock information
From: Srinivas Neeli
Date: Sun Jun 26 2022 - 03:08:54 EST
Added clock information and deprecated calibration support.
Signed-off-by: Srinivas Neeli <srinivas.neeli@xxxxxxxxxx>
Reviewed-by: Rob Herring <robh@xxxxxxxxxx>
---
Changes in V10:
-resolved dt_check error.
Changes in V9:
-Updated clock information in clock-names.
Changes in V8:
-None
Changes in V7:
-None
Changes in V6:
-Removed dtc warnings.
Changes in V5:
-Removed quotes and _clk suffix from clocknames.
Changes in V4:
- Deprecated calibrtion support
Changes in V3:
- New patch
---
.../devicetree/bindings/rtc/xlnx,zynqmp-rtc.yaml | 12 +++++++++++-
1 file changed, 11 insertions(+), 1 deletion(-)
diff --git a/Documentation/devicetree/bindings/rtc/xlnx,zynqmp-rtc.yaml b/Documentation/devicetree/bindings/rtc/xlnx,zynqmp-rtc.yaml
index bdb72d3ddf2a..7ed0230f6c67 100644
--- a/Documentation/devicetree/bindings/rtc/xlnx,zynqmp-rtc.yaml
+++ b/Documentation/devicetree/bindings/rtc/xlnx,zynqmp-rtc.yaml
@@ -23,8 +23,15 @@ properties:
reg:
maxItems: 1
+ clocks:
+ maxItems: 1
+
+ clock-names:
+ items:
+ - const: rtc
+
interrupts:
- minItems: 2
+ maxItems: 2
interrupt-names:
items:
@@ -39,6 +46,7 @@ properties:
minimum: 0x1
maximum: 0x1FFFFF
default: 0x198233
+ deprecated: true
required:
- compatible
@@ -61,5 +69,7 @@ examples:
interrupts = <0 26 4>, <0 27 4>;
interrupt-names = "alarm", "sec";
calibration = <0x198233>;
+ clock-names = "rtc";
+ clocks = <&rtc_clk>;
};
};
--
2.25.1