Hi Daniel,
Thanks for your work.
On 2022-07-10 23:24:07 +0200, Daniel Lezcano wrote:
The thermal OF code has a new API allowing to migrate the OFI tested this together with the series it depends on and while
initialization to a simpler approach.
Use this new API.
temperature monitoring seems to work fine it breaks the emul_temp
interface (/sys/class/thermal/thermal_zone2/emul_temp).
Before this change I can write a temperature to this file and have it
trigger actions, in my test-case changing the cooling state, which I
observe in /sys/class/thermal/cooling_device0/cur_state.
Likewise before this change I could trip the critical trip-point that
would power off the board using the emul_temp interface, this too no
longer works,
echo 120000 > /sys/class/thermal/thermal_zone2/emul_temp
Is this an intention change of the new API?