Re: [PATCH v5 3/5] iio: pressure: bmp280: Add support for BMP380 sensor family
From: Jonathan Cameron
Date: Sun Aug 14 2022 - 10:00:51 EST
On Fri, 12 Aug 2022 12:47:20 +0200
Angel Iglesias <ang.iglesiasg@xxxxxxxxx> wrote:
> On lun, 2022-08-08 at 11:08 +0200, Andy Shevchenko wrote:
> > On Sun, Aug 7, 2022 at 1:56 PM Angel Iglesias <ang.iglesiasg@xxxxxxxxx> wrote:
> > >
> > > Adds compatibility with the new generation of this sensor, the BMP380
> > >
> > > Includes basic sensor initialization to do pressure and temp
> > > measurements and allows tuning oversampling settings for each channel.
> > >
> > > The compensation algorithms are adapted from the device datasheet and
> > > the repository https://github.com/BoschSensortec/BMP3-Sensor-API
> >
> > Missed period.
> >
> > ...
> >
> > > *
> > > https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMP180-DS000-121.pdf
> > > *
> > > https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMP280-DS001-12.pdf
> > > *
> > > https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BME280_DS001-11.pdf
> >
> > Seems like the above links are unresponsive now? Perhaps you may fix
> > them as well in a separate patch?
>
> Sure. Should I include this patch in this next version of this series, or should
> I send the patch as a standalone change?
Either way is fine. Thanks for tidying this up!
>
> > > + *
> > > https://www.bosch-sensortec.com/media/boschsensortec/downloads/datasheets/bst-bmp388-ds001.pdf
> >
> > ...
> >
> > > +/* See datasheet Section 3.11.1. */
> >
> > Again, a bit of consistency in (one-line) comments, please.
> >
> > > +struct bmp380_calib {
> > > + u16 T1;
> > > + u16 T2;
> > > + s8 T3;
> > > + s16 P1;
> > > + s16 P2;
> > > + s8 P3;
> > > + s8 P4;
> > > + u16 P5;
> > > + u16 P6;
> > > + s8 P7;
> > > + s8 P8;
> > > + s16 P9;
> > > + s8 P10;
> > > + s8 P11;
> > > +};
> >
> > __packed ?
Nope - the unpacking is done on filling this array.
Could reorder to reduce size a little but given the naming vs datasheet
that would look very odd. I'd leave this as it is.
> >
> > > + /* Compensated pressure is in cPa (centipascals) */
> > > + *val2 = 100000;
> >
> > Anything to use from units.h?
Not sure we want to add centi to killo conversion!
That combination is rather rare.
Jonathan