Re: [PATCH v6 1/2] power: domain: handle genpd correctly when needing interrupts

From: Martin Kepplinger
Date: Mon Aug 22 2022 - 04:38:57 EST


Am Freitag, dem 19.08.2022 um 16:53 +0200 schrieb Ulf Hansson:
> On Fri, 19 Aug 2022 at 11:17, Martin Kepplinger
> <martin.kepplinger@xxxxxxx> wrote:
> >
> > Am Dienstag, dem 26.07.2022 um 17:07 +0200 schrieb Ulf Hansson:
> > > On Tue, 26 Jul 2022 at 10:33, Martin Kepplinger
> > > <martin.kepplinger@xxxxxxx> wrote:
> > > >
> > > > If for example the power-domains' power-supply node (regulator)
> > > > needs
> > > > interrupts to work, the current setup with noirq callbacks
> > > > cannot
> > > > work; for example a pmic regulator on i2c, when suspending,
> > > > usually
> > > > already
> > > > times out during suspend_noirq:
> > > >
> > > > [   41.024193] buck4: failed to disable: -ETIMEDOUT
> > > >
> > > > So fix system suspend and resume for these power-domains by
> > > > using
> > > > the
> > > > "outer" suspend/resume callbacks instead. Tested on the imx8mq-
> > > > librem5 board,
> > > > but by looking at the dts, this will fix imx8mq-evk and
> > > > possibly
> > > > many other
> > > > boards too.
> > > >
> > > > This is designed so that genpd providers just say "this genpd
> > > > needs
> > > > interrupts" (by setting the flag) - without implying an
> > > > implementation.
> > > >
> > > > Initially system suspend problems had been discussed at
> > > > https://lore.kernel.org/linux-arm-kernel/20211002005954.1367653-8-l.stach@xxxxxxxxxxxxxx/
> > > > which led to discussing the pmic that contains the regulators
> > > > which
> > > > serve as power-domain power-supplies:
> > > > https://lore.kernel.org/linux-pm/573166b75e524517782471c2b7f96e03fd93d175.camel@xxxxxxx/T/
> > > >
> > > > Signed-off-by: Martin Kepplinger <martin.kepplinger@xxxxxxx>
> > > > ---
> > > >  drivers/base/power/domain.c | 13 +++++++++++--
> > > >  include/linux/pm_domain.h   |  5 +++++
> > > >  2 files changed, 16 insertions(+), 2 deletions(-)
> > > >
> > > > diff --git a/drivers/base/power/domain.c
> > > > b/drivers/base/power/domain.c
> > > > index 5a2e0232862e..58376752a4de 100644
> > > > --- a/drivers/base/power/domain.c
> > > > +++ b/drivers/base/power/domain.c
> > > > @@ -130,6 +130,7 @@ static const struct genpd_lock_ops
> > > > genpd_spin_ops = {
> > > >  #define genpd_is_active_wakeup(genpd)  (genpd->flags &
> > > > GENPD_FLAG_ACTIVE_WAKEUP)
> > > >  #define genpd_is_cpu_domain(genpd)     (genpd->flags &
> > > > GENPD_FLAG_CPU_DOMAIN)
> > > >  #define genpd_is_rpm_always_on(genpd)  (genpd->flags &
> > > > GENPD_FLAG_RPM_ALWAYS_ON)
> > > > +#define genpd_irq_on(genpd)            (genpd->flags &
> > > > GENPD_FLAG_IRQ_ON)
> > > >
> > > >  static inline bool irq_safe_dev_in_sleep_domain(struct device
> > > > *dev,
> > > >                 const struct generic_pm_domain *genpd)
> > > > @@ -2065,8 +2066,15 @@ int pm_genpd_init(struct
> > > > generic_pm_domain
> > > > *genpd,
> > > >         genpd->domain.ops.runtime_suspend =
> > > > genpd_runtime_suspend;
> > > >         genpd->domain.ops.runtime_resume =
> > > > genpd_runtime_resume;
> > > >         genpd->domain.ops.prepare = genpd_prepare;
> > > > -       genpd->domain.ops.suspend_noirq = genpd_suspend_noirq;
> > > > -       genpd->domain.ops.resume_noirq = genpd_resume_noirq;
> > > > +
> > > > +       if (genpd_irq_on(genpd)) {
> > > > +               genpd->domain.ops.suspend =
> > > > genpd_suspend_noirq;
> > > > +               genpd->domain.ops.resume = genpd_resume_noirq;
> > > > +       } else {
> > > > +               genpd->domain.ops.suspend_noirq =
> > > > genpd_suspend_noirq;
> > > > +               genpd->domain.ops.resume_noirq =
> > > > genpd_resume_noirq;
> > >
> > > As we discussed previously, I am thinking that it may be better
> > > to
> > > move to using genpd->domain.ops.suspend_late and
> > > genpd->domain.ops.resume_early instead.
> >
> > Wouldn't that better be a separate patch (on top)? Do you really
> > want
> > me to change the current behaviour (default case) to from noirq to
> > late? Then I'll resend this series with such a patch added.
>
> Sorry, I wasn't clear enough, the default behaviour should remain as
> is.
>
> What I meant was, when genpd_irq_on() is true, we should use the
> genpd->domain.ops.suspend_late and genpd->domain.ops.resume_early.

Testing that shows that this isn't working. I can provide the logs
later, but suspend fails and I think it makes sense: "suspend_late" is
simply already too late when i2c (or any needed driver) uses "suspend".

>
> Kind regards
> Uffe