Re: [PATCH v3 04/19] dt-bindings: hwmon: (mr75203) change "reset" property to be optional

From: Farber, Eliav
Date: Wed Aug 31 2022 - 05:44:03 EST


On 8/31/2022 11:21 AM, Philipp Zabel wrote:
On Di, 2022-08-30 at 19:21 +0000, Eliav Farber wrote:
Change "reset" property to be optional instead of required, for SOCs that
don't support a reset controller.

Signed-off-by: Eliav Farber <farbere@xxxxxxxxxx>
---
V3 -> v2:
- Change "reset" property to be optional instead of adding new
  "reset-control-skip" property.

 Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml | 1 -
 1 file changed, 1 deletion(-)

diff --git a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
index 6abde48b746e..2ec4b9da4b92 100644
--- a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
+++ b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
@@ -49,7 +49,6 @@ required:
   - reg
   - reg-names
   - clocks
-  - resets

Is this just for mr76006? Or does mr75203 work without reset as well?

If it is the former, maybe a new compatible should be added and resets
should be kept required

mr75203 also works without a reset.
As I replied in PATCH v3 14/19, series 5/6 is relevant only for the
temperature sensor.
The “reset” property is relevant to the controller.

--
Regards, Eliav