On Tue, Aug 30, 2022 at 07:22:06PM +0000, Eliav Farber wrote:Fixed.
Modify the equation and coefficients used to convert the digital output
to temperature according to series 5 of the Moortec Embedded Temperature
Sensor (METS) datasheet:
T = G + H * (n / cal5 - 0.5) + J * F
Where:
*) G = 60, H = 200, cal5 = 4094, J = -0.1.
*) F = frequency clock in MHz.
*) n is the digital output.
In code, the G, H and J coefficients are multiplied by a factor of 1000
to get the temperature in milli-Celsius.
Final result is clamped in case it exceeds min/max thresholds.
Change is done since it is not clear where the current equation and
not clear -> unclear
coefficients came from.
...
+#define PVT_TEMP_MIN -40000
+#define PVT_TEMP_MAX 125000
Unit suffix? _mC perhaps would be enough.