[PATCH v6 0/2] iio: pressure: dps310: Reset chip if MEAS_CFG is corrupt

From: Eddie James
Date: Tue Sep 06 2022 - 16:11:39 EST


The DPS310 chip has been observed to get "stuck" such that pressure
and temperature measurements are never indicated as "ready" in the
MEAS_CFG register. The only solution is to reset the device and try
again. In order to avoid continual failures, use a boolean flag to
only try the reset after timeout once if errors persist. Include a
patch to move the startup procedure into a function.

Changes since v5:
- Completely rework the second patch to reset and reinit in any
timeout condition, if there haven't been previous timeouts that
failed to recover the chip.

Changes since v4:
- Just check for rc rather than rc < 0 in some cases
- Split declaration and init of rc

Changes since v3:
- Don't check regmap* return codes for < 0
- Fix comment spelling

Changes since v2:
- Add some comments
- Fix the clunky control flow

Changes since v1:
- Separate into two patches
- Rename 'dps310_verify_meas_cfg' to 'dps310_check_reset_meas_cfg'

Eddie James (2):
iio: pressure: dps310: Refactor startup procedure
iio: pressure: dps310: Reset chip after timeout

drivers/iio/pressure/dps310.c | 266 +++++++++++++++++++++-------------
1 file changed, 167 insertions(+), 99 deletions(-)

--