Re: [PATCH] spi: meson-spicc: do not rely on busy flag in pow2 clk ops
From: Markus Schneider-Pargmann
Date: Thu Sep 08 2022 - 08:32:49 EST
Hi Neil,
thanks for fixing.
On Thu, Sep 08, 2022 at 02:18:03PM +0200, Neil Armstrong wrote:
> Since [1], controller's busy flag isn't set anymore when the
> __spi_transfer_message_noqueue() is used instead of the
> __spi_pump_transfer_message() logic for spi_sync transfers.
>
> Since the pow2 clock ops were limited to only be available when a
> transfer is ongoing (between prepare_transfer_hardware and
> unprepare_transfer_hardware callbacks), the only way to track this
> down is to check for the controller cur_msg.
>
> [1] ae7d2346dc89 ("spi: Don't use the message queue if possible in spi_sync")
>
> Fixes: 09992025dacd ("spi: meson-spicc: add local pow2 clock ops to preserve rate between messages")
> Fixes: ae7d2346dc89 ("spi: Don't use the message queue if possible in spi_sync")
> Reported-by: Markus Schneider-Pargmann <msp@xxxxxxxxxxxx>
> Signed-off-by: Neil Armstrong <narmstrong@xxxxxxxxxxxx>
Tested-by: Markus Schneider-Pargmann <msp@xxxxxxxxxxxx>
Best,
Markus
> ---
> drivers/spi/spi-meson-spicc.c | 6 +++---
> 1 file changed, 3 insertions(+), 3 deletions(-)
>
> diff --git a/drivers/spi/spi-meson-spicc.c b/drivers/spi/spi-meson-spicc.c
> index e4cb52e1fe26..6974a1c947aa 100644
> --- a/drivers/spi/spi-meson-spicc.c
> +++ b/drivers/spi/spi-meson-spicc.c
> @@ -537,7 +537,7 @@ static unsigned long meson_spicc_pow2_recalc_rate(struct clk_hw *hw,
> struct clk_divider *divider = to_clk_divider(hw);
> struct meson_spicc_device *spicc = pow2_clk_to_spicc(divider);
>
> - if (!spicc->master->cur_msg || !spicc->master->busy)
> + if (!spicc->master->cur_msg)
> return 0;
>
> return clk_divider_ops.recalc_rate(hw, parent_rate);
> @@ -549,7 +549,7 @@ static int meson_spicc_pow2_determine_rate(struct clk_hw *hw,
> struct clk_divider *divider = to_clk_divider(hw);
> struct meson_spicc_device *spicc = pow2_clk_to_spicc(divider);
>
> - if (!spicc->master->cur_msg || !spicc->master->busy)
> + if (!spicc->master->cur_msg)
> return -EINVAL;
>
> return clk_divider_ops.determine_rate(hw, req);
> @@ -561,7 +561,7 @@ static int meson_spicc_pow2_set_rate(struct clk_hw *hw, unsigned long rate,
> struct clk_divider *divider = to_clk_divider(hw);
> struct meson_spicc_device *spicc = pow2_clk_to_spicc(divider);
>
> - if (!spicc->master->cur_msg || !spicc->master->busy)
> + if (!spicc->master->cur_msg)
> return -EINVAL;
>
> return clk_divider_ops.set_rate(hw, rate, parent_rate);
> --
> 2.25.1
>