[PATCH] hwmon: (aquacomputer_d5next) Fix Quadro fan speed offsets

From: Aleksa Savic
Date: Wed Sep 14 2022 - 07:45:35 EST


The offsets for setting speeds of fans connected to Quadro are off by one.
Set them to their correct values.

The offsets as shown point to registers for setting the fan control mode,
which will be explored in future patches, but slipped in here. When
setting fan speeds, the resulting values were overlapping, which made the
fans still run in my initial testing.

Fixes: cdbe34da01e3 ("hwmon: (aquacomputer_d5next) Add support for Aquacomputer Quadro fan controller")
Signed-off-by: Aleksa Savic <savicaleksa83@xxxxxxxxx>
---
drivers/hwmon/aquacomputer_d5next.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/hwmon/aquacomputer_d5next.c b/drivers/hwmon/aquacomputer_d5next.c
index 3ea25edfc7a5..c51a2678f0eb 100644
--- a/drivers/hwmon/aquacomputer_d5next.c
+++ b/drivers/hwmon/aquacomputer_d5next.c
@@ -120,7 +120,7 @@ static u16 octo_ctrl_fan_offsets[] = { 0x5B, 0xB0, 0x105, 0x15A, 0x1AF, 0x204, 0
static u8 quadro_sensor_fan_offsets[] = { 0x70, 0x7D, 0x8A, 0x97 };

/* Fan speed registers in Quadro control report (from 0-100%) */
-static u16 quadro_ctrl_fan_offsets[] = { 0x36, 0x8b, 0xe0, 0x135 };
+static u16 quadro_ctrl_fan_offsets[] = { 0x37, 0x8c, 0xe1, 0x136 };

/* Register offsets for the High Flow Next */
#define HIGHFLOWNEXT_NUM_SENSORS 2
--
2.30.2