Re: [PATCH v2 00/41] drm: Analog TV Improvements

From: Maxime Ripard
Date: Wed Sep 21 2022 - 10:03:45 EST


On Wed, Sep 07, 2022 at 06:44:53PM +0200, Noralf Trønnes wrote:
>
>
> Den 07.09.2022 12.36, skrev Stefan Wahren:
> > Hi Maxime,
> >
> > Am 05.09.22 um 16:57 schrieb Maxime Ripard:
> >> On Fri, Sep 02, 2022 at 01:28:16PM +0200, Noralf Trønnes wrote:
> >>>
> >>> Den 01.09.2022 21.35, skrev Noralf Trønnes:
> >>>>
> >>>> I have finally found a workaround for my kernel hangs.
> >>>>
> >>>> Dom had a look at my kernel and found that the VideoCore was fine, and
> >>>> he said this:
> >>>>
> >>>>> That suggests cause of lockup was on arm side rather than VC side.
> >>>>>
> >>>>> But it's hard to diagnose further. Once you've had a peripheral not
> >>>>> respond, the AXI bus locks up and no further operations are possible.
> >>>>> Usual causes of this are required clocks being stopped or domains
> >>>>> disabled and then trying to access the hardware.
> >>>>>
> >>>> So when I got this on my 64-bit build:
> >>>>
> >>>> [  166.702171] SError Interrupt on CPU1, code 0x00000000bf000002 --
> >>>> SError
> >>>> [  166.702187] CPU: 1 PID: 8 Comm: kworker/u8:0 Tainted: G        W
> >>>>      5.19.0-rc6-00096-gba7973977976-dirty #1
> >>>> [  166.702200] Hardware name: Raspberry Pi 4 Model B Rev 1.1 (DT)
> >>>> [  166.702206] Workqueue: events_freezable_power_
> >>>> thermal_zone_device_check
> >>>> [  166.702231] pstate: 200000c5 (nzCv daIF -PAN -UAO -TCO -DIT -SSBS
> >>>> BTYPE=--)
> >>>> [  166.702242] pc : regmap_mmio_read32le+0x10/0x28
> >>>> [  166.702261] lr : regmap_mmio_read+0x44/0x70
> >>>> ...
> >>>> [  166.702606]  bcm2711_get_temp+0x58/0xb0 [bcm2711_thermal]
> >>>>
> >>>> I wondered if that reg read was stalled due to a clock being stopped.
> >>>>
> >>>> Lo and behold, disabling runtime pm and keeping the vec clock running
> >>>> all the time fixed it[1].
> >>>>
> >>>> I don't know what the problem is, but at least I can now test this
> >>>> patchset.
> >>>>
> >>>> [1] https://gist.github.com/notro/23b984e7fa05cfbda2db50a421cac065
> >>>>
> >>> It turns out I didn't have to disable runtime pm:
> >>> https://gist.github.com/notro/0adcfcb12460b54e54458afe11dc8ea2
> >> If the bcm2711_thermal IP needs that clock to be enabled, it should grab
> >> a reference itself, but it looks like even the device tree binding
> >> doesn't ask for one.
> > The missing clock in the device tree binding is expected, because
> > despite of the code there is not much information about the BCM2711
> > clock tree. But i'm skeptical that the AVS IP actually needs the VEC
> > clock, i think it's more likely that the VEC clock parent is changed and
> > that cause this issue. I could take care of the bcm2711 binding & driver
> > if i know which clock is really necessary.
>
> Seems you're right, keeping the parent always enabled is enough:
>
> clk_prepare_enable(clk_get_parent(vec->clock)); // pllc_per
>
> I tried enabling just the grandparent clock as well, but that didn't help.

Yeah, adding tracing to the clock framework shows that it indeed
disables PLLC_PER. So there's probably some other device that depends on
it but doesn't take a reference to it.

I had a look, but it's not really obvious what that might be.

This patch makes sure that the PLL*_PER are never disabled, could you
test it? It seems to work for me.


diff --git a/drivers/clk/bcm/clk-bcm2835.c b/drivers/clk/bcm/clk-bcm2835.c
index 48a1eb9f2d55..3839261ee419 100644
--- a/drivers/clk/bcm/clk-bcm2835.c
+++ b/drivers/clk/bcm/clk-bcm2835.c
@@ -1675,7 +1675,7 @@ static const struct bcm2835_clk_desc clk_desc_array[] = {
.load_mask = CM_PLLA_LOADPER,
.hold_mask = CM_PLLA_HOLDPER,
.fixed_divider = 1,
- .flags = CLK_SET_RATE_PARENT),
+ .flags = CLK_IS_CRITICAL | CLK_SET_RATE_PARENT),
[BCM2835_PLLA_DSI0] = REGISTER_PLL_DIV(
SOC_ALL,
.name = "plla_dsi0",
@@ -1784,7 +1784,7 @@ static const struct bcm2835_clk_desc clk_desc_array[] = {
.load_mask = CM_PLLC_LOADPER,
.hold_mask = CM_PLLC_HOLDPER,
.fixed_divider = 1,
- .flags = CLK_SET_RATE_PARENT),
+ .flags = CLK_IS_CRITICAL | CLK_SET_RATE_PARENT),

/*
* PLLD is the display PLL, used to drive DSI display panels.
@@ -1891,7 +1891,7 @@ static const struct bcm2835_clk_desc clk_desc_array[] = {
.load_mask = CM_PLLH_LOADAUX,
.hold_mask = 0,
.fixed_divider = 1,
- .flags = CLK_SET_RATE_PARENT),
+ .flags = CLK_IS_CRITICAL | CLK_SET_RATE_PARENT),
[BCM2835_PLLH_PIX] = REGISTER_PLL_DIV(
SOC_BCM2835,
.name = "pllh_pix",


Maxime

Attachment: signature.asc
Description: PGP signature