[PATCH 6.0 08/17] hwmon: (aquacomputer_d5next) Fix Quadro fan speed offsets
From: Greg Kroah-Hartman
Date: Mon Oct 10 2022 - 03:06:14 EST
From: Aleksa Savic <savicaleksa83@xxxxxxxxx>
commit b7f3e9650f12d1e06b94a0257bcb90279f691bf5 upstream.
The offsets for setting speeds of fans connected to Quadro are off by one.
Set them to their correct values.
The offsets as shown point to registers for setting the fan control mode,
which will be explored in future patches, but slipped in here. When
setting fan speeds, the resulting values were overlapping, which made the
fans still run in my initial testing.
Fixes: cdbe34da01e3 ("hwmon: (aquacomputer_d5next) Add support for Aquacomputer Quadro fan controller")
Signed-off-by: Aleksa Savic <savicaleksa83@xxxxxxxxx>
Link: https://lore.kernel.org/r/20220914114327.6941-1-savicaleksa83@xxxxxxxxx
Cc: stable@xxxxxxxxxxxxxxx
Signed-off-by: Guenter Roeck <linux@xxxxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>
---
drivers/hwmon/aquacomputer_d5next.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
--- a/drivers/hwmon/aquacomputer_d5next.c
+++ b/drivers/hwmon/aquacomputer_d5next.c
@@ -110,7 +110,7 @@ static u16 octo_ctrl_fan_offsets[] = { 0
static u8 quadro_sensor_fan_offsets[] = { 0x70, 0x7D, 0x8A, 0x97 };
/* Fan speed registers in Quadro control report (from 0-100%) */
-static u16 quadro_ctrl_fan_offsets[] = { 0x36, 0x8b, 0xe0, 0x135 };
+static u16 quadro_ctrl_fan_offsets[] = { 0x37, 0x8c, 0xe1, 0x136 };
/* Labels for D5 Next */
static const char *const label_d5next_temp[] = {