[PATCH v5 3/3] ARM: dts: armada-375: Update network description to match schema

From: Michał Grzelak
Date: Fri Oct 14 2022 - 17:33:58 EST


From: Marcin Wojtas <mw@xxxxxxxxxxxx>

Update the PP2 ethernet ports subnodes' names to match
schema enforced by the marvell,pp2.yaml contents.

Add new required properties ('reg') which contains information
about the port ID, keeping 'port-id' ones for backward
compatibility.

Signed-off-by: Marcin Wojtas <mw@xxxxxxxxxxxx>
---
arch/arm/boot/dts/armada-375.dtsi | 12 ++++++++----
1 file changed, 8 insertions(+), 4 deletions(-)

diff --git a/arch/arm/boot/dts/armada-375.dtsi b/arch/arm/boot/dts/armada-375.dtsi
index 929deaf312a5..9fbe0cfec48f 100644
--- a/arch/arm/boot/dts/armada-375.dtsi
+++ b/arch/arm/boot/dts/armada-375.dtsi
@@ -178,6 +178,8 @@ mdio: mdio@c0054 {

/* Network controller */
ethernet: ethernet@f0000 {
+ #address-cells = <1>;
+ #size-cells = <0>;
compatible = "marvell,armada-375-pp2";
reg = <0xf0000 0xa000>, /* Packet Processor regs */
<0xc0000 0x3060>, /* LMS regs */
@@ -187,15 +189,17 @@ ethernet: ethernet@f0000 {
clock-names = "pp_clk", "gop_clk";
status = "disabled";

- eth0: eth0 {
+ eth0: ethernet-port@0 {
interrupts = <GIC_SPI 37 IRQ_TYPE_LEVEL_HIGH>;
- port-id = <0>;
+ reg = <0>;
+ port-id = <0>; /* For backward compatibility. */
status = "disabled";
};

- eth1: eth1 {
+ eth1: ethernet-port@1 {
interrupts = <GIC_SPI 41 IRQ_TYPE_LEVEL_HIGH>;
- port-id = <1>;
+ reg = <1>;
+ port-id = <1>; /* For backward compatibility. */
status = "disabled";
};
};
--
2.37.3