[PATCH 08/11] phy: tegra: xusb: Disable trk clk when not using

From: Wayne Chang
Date: Mon Oct 24 2022 - 03:43:17 EST


The change fixes an issue that the pad tracking is a one-time calibration
for Tegra186 and Tegra194. We should disable the clk when it is done.
The 100us delay is for HW recording the calibration value.

Signed-off-by: Wayne Chang <waynec@xxxxxxxxxx>
---
drivers/phy/tegra/xusb-tegra186.c | 6 ++++--
1 file changed, 4 insertions(+), 2 deletions(-)

diff --git a/drivers/phy/tegra/xusb-tegra186.c b/drivers/phy/tegra/xusb-tegra186.c
index 0996ede63387..f121b4ffbbfd 100644
--- a/drivers/phy/tegra/xusb-tegra186.c
+++ b/drivers/phy/tegra/xusb-tegra186.c
@@ -609,6 +609,10 @@ static void tegra186_utmi_bias_pad_power_on(struct tegra_xusb_padctl *padctl)
value &= ~USB2_PD_TRK;
padctl_writel(padctl, value, XUSB_PADCTL_USB2_BIAS_PAD_CTL1);

+ udelay(100);
+
+ clk_disable_unprepare(priv->usb2_trk_clk);
+
mutex_unlock(&padctl->lock);
}

@@ -633,8 +637,6 @@ static void tegra186_utmi_bias_pad_power_off(struct tegra_xusb_padctl *padctl)
value |= USB2_PD_TRK;
padctl_writel(padctl, value, XUSB_PADCTL_USB2_BIAS_PAD_CTL1);

- clk_disable_unprepare(priv->usb2_trk_clk);
-
mutex_unlock(&padctl->lock);
}

--
2.25.1