Re: [PATCH net-next v4 4/4] net: dsa: microchip: ksz8: add MTU configuration support

From: Oleksij Rempel
Date: Fri Nov 11 2022 - 00:30:02 EST


On Thu, Nov 10, 2022 at 03:03:25PM +0200, Vladimir Oltean wrote:
> On Thu, Nov 10, 2022 at 01:22:25PM +0100, Oleksij Rempel wrote:
> > Make MTU configurable on KSZ87xx and KSZ88xx series of switches.
> >
> > Before this patch, pre-configured behavior was different on different
> > switch series, due to opposite meaning of the same bit:
> > - KSZ87xx: Reg 4, Bit 1 - if 1, max frame size is 1532; if 0 - 1514
> > - KSZ88xx: Reg 4, Bit 1 - if 1, max frame size is 1514; if 0 - 1532
> >
> > Since the code was telling "... SW_LEGAL_PACKET_DISABLE, true)", I
> > assume, the idea was to set max frame size to 1532.
> >
> > With this patch, by setting MTU size 1500, both switch series will be
> > configured to the 1532 frame limit.
> >
> > This patch was tested on KSZ8873.
> >
> > Signed-off-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx>
> > Acked-by: Arun Ramadoss <arun.ramadoss@xxxxxxxxxxxxx>
> > ---
>
> Reviewed-by: Vladimir Oltean <olteanv@xxxxxxxxx>
>
> As an extension to this patch set, you might also want to set
> ds->mtu_enforcement_ingress = true, to activate the bridge MTU
> normalization logic, since you have one MTU global to the entire switch.

Ok, I'll include it in to a different patch set. There are more patches
to mainline :)

Regards,
Oleksij
--