Switch to gpiod_set_value_cansleep() in sii902x_reset().Reviewed-by: Andrzej Hajda <andrzej.hajda@xxxxxxxxx>
This is relevant if the reset line is tied to a I2C GPIO
controller.
Signed-off-by: Wadim Egorov <w.egorov@xxxxxxxxx>
---
drivers/gpu/drm/bridge/sii902x.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)
diff --git a/drivers/gpu/drm/bridge/sii902x.c b/drivers/gpu/drm/bridge/sii902x.c
index 878fb7d3732b..980611aec2f6 100644
--- a/drivers/gpu/drm/bridge/sii902x.c
+++ b/drivers/gpu/drm/bridge/sii902x.c
@@ -240,12 +240,12 @@ static void sii902x_reset(struct sii902x *sii902x)
if (!sii902x->reset_gpio)
return;
- gpiod_set_value(sii902x->reset_gpio, 1);
+ gpiod_set_value_cansleep(sii902x->reset_gpio, 1);
/* The datasheet says treset-min = 100us. Make it 150us to be sure. */
usleep_range(150, 200);
- gpiod_set_value(sii902x->reset_gpio, 0);
+ gpiod_set_value_cansleep(sii902x->reset_gpio, 0);
}
static enum drm_connector_status sii902x_detect(struct sii902x *sii902x)