[PATCH v1 05/20] ARM: dts: imx6qdl: use enet_clk_ref instead of enet_out for the FEC node

From: Oleksij Rempel
Date: Fri Jan 13 2023 - 09:34:31 EST


Old imx6q machine code makes RGMII/RMII clock direction decision based on
configuration of "ptp" clock. "enet_out" is not used and make no real
sense, since we can't configure it as output or use it as clock
provider.

Instead of "enet_out" use "enet_clk_ref" which is actual selector to
choose between internal and external clock source:

FEC MAC <---------- enet_clk_ref <--------- SoC PLL
\
^------<-> refclock PAD (bi directional)

Signed-off-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx>
---
arch/arm/boot/dts/imx6qdl.dtsi | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/arch/arm/boot/dts/imx6qdl.dtsi b/arch/arm/boot/dts/imx6qdl.dtsi
index ff1e0173b39b..71522263031a 100644
--- a/arch/arm/boot/dts/imx6qdl.dtsi
+++ b/arch/arm/boot/dts/imx6qdl.dtsi
@@ -1050,8 +1050,8 @@ fec: ethernet@2188000 {
clocks = <&clks IMX6QDL_CLK_ENET>,
<&clks IMX6QDL_CLK_ENET>,
<&clks IMX6QDL_CLK_ENET_REF>,
- <&clks IMX6QDL_CLK_ENET_REF>;
- clock-names = "ipg", "ahb", "ptp", "enet_out";
+ <&clks IMX6QDL_CLK_ENET_REF_SEL>;
+ clock-names = "ipg", "ahb", "ptp", "enet_clk_ref";
fsl,stop-mode = <&gpr 0x34 27>;
status = "disabled";
};
--
2.30.2