Re: [PATCH net-next v2 0/8] Adding Sparx5 IS0 VCAP support

From: Dan Carpenter
Date: Tue Jan 24 2023 - 05:58:01 EST


On Tue, Jan 24, 2023 at 11:45:03AM +0100, Steen Hegelund wrote:
> This provides the Ingress Stage 0 (IS0) VCAP (Versatile Content-Aware
> Processor) support for the Sparx5 platform.
>
> The IS0 VCAP (also known in the datasheet as CLM) is a classifier VCAP that
> mainly extracts frame information to metadata that follows the frame in the
> Sparx5 processing flow all the way to the egress port.
>
> The IS0 VCAP has 4 lookups and they are accessible with a TC chain id:
>
> - chain 1000000: IS0 Lookup 0
> - chain 1100000: IS0 Lookup 1
> - chain 1200000: IS0 Lookup 2
> - chain 1300000: IS0 Lookup 3
> - chain 1400000: IS0 Lookup 4
> - chain 1500000: IS0 Lookup 5
>
> Each of these lookups have their own port keyset configuration that decides
> which keys will be used for matching on which traffic type.
>
> The IS0 VCAP has these traffic classifications:
>
> - IPv4 frames
> - IPv6 frames
> - Unicast MPLS frames (ethertype = 0x8847)
> - Multicast MPLS frames (ethertype = 0x8847)
> - Other frame types than MPLS, IPv4 and IPv6
>
> The IS0 VCAP has an action that allows setting the value of a PAG (Policy
> Association Group) key field in the frame metadata, and this can be used
> for matching in an IS2 VCAP rule.
>
> This allow rules in the IS0 VCAP to be linked to rules in the IS2 VCAP.
>
> The linking is exposed by using the TC "goto chain" action with an offset
> from the IS2 chain ids.
>
> As an example a "goto chain 8000001" will use a PAG value of 1 to chain to
> a rule in IS2 Lookup 0.
>
> Version History:
> ================
> v2 Added corrections suggested by Dan Carpenter.

Thanks!

regards,
dan carpenter