Re: [PATCH v7 4/4] thermal: mediatek: add another get_temp ops for thermal sensors

From: Daniel Lezcano
Date: Tue Jan 24 2023 - 11:55:08 EST



Hi Amjad,

On 24/01/2023 11:08, Amjad Ouled-Ameur wrote:

[ ... ]


IIUC, there is a sensor per couple of cores. 1 x 2Bigs, 1 x 2Bigs, 1 x 4 Little, right ?

MT8365 SoC has 4 x A53 CPUs. The SoC has 4 thermal zones per sensor. Thermal zone 0 corresponds

to all 4 x A53 CPUs, the other thermal zones (1, 2 and 3) has nothing to do with CPUs. The cooling device type

used for CPUs is passive. FYI, thermal zones 1, 2 and 3 are present in the SoC for debug-purpose only, they are not supposed

to be used for production.

After reconsidering the fact that zones 1, 2 and 3 are only used for dev/debug, it might be best to avo >
aggregation as you suggested, and keep only support for zone 0 in this driver. Thus I suggest I send a V8

where I keep only below fixes for this patch if that's okay with you:

- Define "raw_to_mcelsius" function pointer for "struct thermal_bank_cfg".

- Fix "mtk_thermal" variable in mtk_read_temp().

- Set "mt->raw_to_mcelsius" in probe().


For zones 1, 2 and 3 we can later add a different driver specific for dev/debug to probe them to

avoid confusion.

You can add them in the driver and in the device tree, but just add the cooling device for the thermal zone 0.


--