From: Matthias Brugger <matthias.bgg@xxxxxxxxx>
This reverts commit fc6634ac0e5380aeb1063275a2e9a583d41b2306.
The mmsys is a clock provider but does not have any clocks connected to
it. Therefore assigned-clock properties should be applied to the users of mmsys.
This fixes the DT schema check:
mediatek/mt8173-elm.dtb: syscon@14000000: 'assigned-clock-rates', 'assigned-clocks' do not match any of the regexes: 'pinctrl-[0-9]+'
Signed-off-by: Matthias Brugger <matthias.bgg@xxxxxxxxx>
---
arch/arm64/boot/dts/mediatek/mt8173.dtsi | 2 --
1 file changed, 2 deletions(-)
diff --git a/arch/arm64/boot/dts/mediatek/mt8173.dtsi b/arch/arm64/boot/dts/mediatek/mt8173.dtsi
index c47d7d900f283..b753547e250fe 100644
--- a/arch/arm64/boot/dts/mediatek/mt8173.dtsi
+++ b/arch/arm64/boot/dts/mediatek/mt8173.dtsi
@@ -988,8 +988,6 @@ mmsys: syscon@14000000 {
compatible = "mediatek,mt8173-mmsys", "syscon";
reg = <0 0x14000000 0 0x1000>;
power-domains = <&spm MT8173_POWER_DOMAIN_MM>;
- assigned-clocks = <&topckgen CLK_TOP_MM_SEL>;
- assigned-clock-rates = <400000000>;
#clock-cells = <1>;
#reset-cells = <1>;
mboxes = <&gce 0 CMDQ_THR_PRIO_HIGHEST>,