Re: [PATCH net-next 2/3] net/sched: taprio: don't allow dynamic max_sdu to go negative after stab adjustment
From: Kurt Kanzenbach
Date: Thu Feb 16 2023 - 04:28:14 EST
On Thu Feb 16 2023, Vladimir Oltean wrote:
> The overhead specified in the size table comes from the user. With small
> time intervals (or gates always closed), the overhead can be larger than
> the max interval for that traffic class, and their difference is
> negative.
>
> What we want to happen is for max_sdu_dynamic to have the smallest
> non-zero value possible (1) which means that all packets on that traffic
> class are dropped on enqueue. However, since max_sdu_dynamic is u32, a
> negative is represented as a large value and oversized dropping never
> happens.
>
> Use max_t with int to force a truncation of max_frm_len to no smaller
> than dev->hard_header_len + 1, which in turn makes max_sdu_dynamic no
> smaller than 1.
>
> Fixes: fed87cc6718a ("net/sched: taprio: automatically calculate queueMaxSDU based on TC gate durations")
> Signed-off-by: Vladimir Oltean <vladimir.oltean@xxxxxxx>
Reviewed-by: Kurt Kanzenbach <kurt@xxxxxxxxxxxxx>
Attachment:
signature.asc
Description: PGP signature