[PATCH v4 3/7] iio: pressure: bmp280: Make read calibration callback optional
From: Angel Iglesias
Date: Sun Feb 19 2023 - 12:00:58 EST
Newer models do not require read the calibration parameters and apply the
compensation algorithms in the sensor.
Suggested-by: Jonathan Cameron <jic23@xxxxxxxxxx>
Signed-off-by: Angel Iglesias <ang.iglesiasg@xxxxxxxxx>
Reviewed-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxxxxxxxx>
diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
index 6467034b1d3e..22addaaa5393 100644
--- a/drivers/iio/pressure/bmp280-core.c
+++ b/drivers/iio/pressure/bmp280-core.c
@@ -1631,10 +1631,12 @@ int bmp280_common_probe(struct device *dev,
* time once. They will not change.
*/
- ret = data->chip_info->read_calib(data);
- if (ret < 0)
- return dev_err_probe(data->dev, ret,
- "failed to read calibration coefficients\n");
+ if (data->chip_info->read_calib) {
+ ret = data->chip_info->read_calib(data);
+ if (ret < 0)
+ return dev_err_probe(data->dev, ret,
+ "failed to read calibration coefficients\n");
+ }
/*
* Attempt to grab an optional EOC IRQ - only the BMP085 has this
--
2.39.2