Add additional modes to trigger the selected LED.
The following modes are supported:
Tx/Rx: Flash LED on data transmission (default)
CTS: DCE Ready to accept data from the DTE.
DSR: DCE is ready to receive and send data.
CAR: DCE is receiving a carrier from a remote DTE.
RNG: DCE has detected an incoming ring signal.
The mode can be changed for example with the following command:
echo "CTS" > /sys/class/leds/<led>/mode
This would turn on the LED, when the DTE(modem) signals the DCE that it
is ready to accept data.
Signed-off-by: Florian Eckert <fe@xxxxxxxxxx>
---
.../ABI/testing/sysfs-class-led-trigger-tty | 16 ++
drivers/leds/trigger/ledtrig-tty.c | 145 ++++++++++++++++--
2 files changed, 146 insertions(+), 15 deletions(-)
diff --git a/Documentation/ABI/testing/sysfs-class-led-trigger-tty b/Documentation/ABI/testing/sysfs-class-led-trigger-tty
index 2bf6b24e781b..4023585d3acf 100644
--- a/Documentation/ABI/testing/sysfs-class-led-trigger-tty
+++ b/Documentation/ABI/testing/sysfs-class-led-trigger-tty
@@ -4,3 +4,19 @@ KernelVersion: 5.10
Contact: linux-leds@xxxxxxxxxxxxxxx
Description:
Specifies the tty device name of the triggering tty
+
+What: /sys/class/leds/<led>/mode
+Date: January 2023
+KernelVersion: 6.3
+Description:
+ Specifies the operating to trigger the LED.
+ The following operating modes are supported:
+ * Tx/Rx: Flash LED on data transmission (default)
+ * CTS: DCE Ready to accept data from the DTE.
+ LED on if line is high.
+ * DSR: DCE is ready to receive and send data.
+ LED on if line is high.
+ * CAR: DCE has detected a carrier from a remote DTE.
+ LED on if line is high.
+ * RNG: DCE has detected an incoming ring signal.
+ LED on if line is high.