[PATCH v1 4/4] ACPI: processor: thermal: Update CPU cooling devices on cpufreq policy changes

From: Rafael J. Wysocki
Date: Fri Mar 03 2023 - 14:24:17 EST


From: Rafael J. Wysocki <rafael.j.wysocki@xxxxxxxxx>

When a cpufreq policy appears or goes away, the CPU cooling devices for
the CPUs covered by that policy need to be updated so that the new
processor_get_max_state() value is stored as max_state and the
statistics in sysfs are rearranged for each of them.

Do that accordingly in acpi_thermal_cpufreq_init() and
acpi_thermal_cpufreq_exit().

Fixes: a365105c685c("thermal: sysfs: Reuse cdev->max_state")
Reported-by: Wang, Quanxian <quanxian.wang@xxxxxxxxx>
Link: https://lore.kernel.org/linux-pm/53ec1f06f61c984100868926f282647e57ecfb2d.camel@xxxxxxxxx/
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@xxxxxxxxx>
---
drivers/acpi/processor_thermal.c | 16 +++++++++++++---
1 file changed, 13 insertions(+), 3 deletions(-)

Index: linux-pm/drivers/acpi/processor_thermal.c
===================================================================
--- linux-pm.orig/drivers/acpi/processor_thermal.c
+++ linux-pm/drivers/acpi/processor_thermal.c
@@ -140,9 +140,14 @@ void acpi_thermal_cpufreq_init(struct cp
ret = freq_qos_add_request(&policy->constraints,
&pr->thermal_req,
FREQ_QOS_MAX, INT_MAX);
- if (ret < 0)
+ if (ret < 0) {
pr_err("Failed to add freq constraint for CPU%d (%d)\n",
cpu, ret);
+ continue;
+ }
+
+ if (!IS_ERR(pr->cdev))
+ thermal_cooling_device_update(pr->cdev);
}
}

@@ -153,8 +158,13 @@ void acpi_thermal_cpufreq_exit(struct cp
for_each_cpu(cpu, policy->related_cpus) {
struct acpi_processor *pr = per_cpu(processors, cpu);

- if (pr)
- freq_qos_remove_request(&pr->thermal_req);
+ if (!pr)
+ continue;
+
+ freq_qos_remove_request(&pr->thermal_req);
+
+ if (!IS_ERR(pr->cdev))
+ thermal_cooling_device_update(pr->cdev);
}
}
#else /* ! CONFIG_CPU_FREQ */