Re: thermal/drivers/tegra: Getting rid of the get_thermal_instance() usage

From: Daniel Lezcano
Date: Wed Mar 08 2023 - 12:23:02 EST



Hi Thierry,

did you have time to look to the changes ?

Or at least a way to remove the get_thermal_instance() usage ?




On 10/02/2023 15:09, Thierry Reding wrote:
On Fri, Feb 10, 2023 at 02:17:03PM +0100, Daniel Lezcano wrote:
Hi Thierry,

On Thu, Jan 26, 2023 at 01:55:52PM +0100, Thierry Reding wrote:
On Tue, Jan 24, 2023 at 08:57:23PM +0100, Daniel Lezcano wrote:

Hi,

does anyone know what is the purpose of the get_thermal_instance() usage in
this code:

https://git.kernel.org/pub/scm/linux/kernel/git/thermal/linux.git/tree/drivers/thermal/tegra/soctherm.c?h=thermal/linux-next#n623

The driver is using a function which is reserved for the thermal core. It
should not.

Is the following change ok ?

diff --git a/drivers/thermal/tegra/soctherm.c
b/drivers/thermal/tegra/soctherm.c
index 220873298d77..5f552402d987 100644
--- a/drivers/thermal/tegra/soctherm.c
+++ b/drivers/thermal/tegra/soctherm.c
@@ -620,9 +620,8 @@ static int tegra_thermctl_set_trip_temp(struct
thermal_zone_device *tz, int trip
continue;

cdev = ts->throt_cfgs[i].cdev;
- if (get_thermal_instance(tz, cdev, trip_id))
- stc = find_throttle_cfg_by_name(ts, cdev->type);
- else
+ stc = find_throttle_cfg_by_name(ts, cdev->type);
+ if (!stc)
continue;

return throttrip_program(dev, sg, stc, temp);
@@ -768,9 +767,9 @@ static int tegra_soctherm_set_hwtrips(struct device
*dev,
continue;

cdev = ts->throt_cfgs[i].cdev;
- if (get_thermal_instance(tz, cdev, trip))
- stc = find_throttle_cfg_by_name(ts, cdev->type);
- else
+
+ stc = find_throttle_cfg_by_name(ts, cdev->type);
+ if (!stc)
continue;

ret = throttrip_program(dev, sg, stc, temperature);

There's a small difference in behavior after applying this patch. Prior
to this I get (on Tegra210):

[ 12.354091] tegra_soctherm 700e2000.thermal-sensor: missing thermtrips, will use critical trips as shut down temp
[ 12.379009] tegra_soctherm 700e2000.thermal-sensor: thermtrip: will shut down when cpu reaches 102500 mC
[ 12.388882] tegra_soctherm 700e2000.thermal-sensor: programming throttle for cpu to 102500
[ 12.401007] tegra_soctherm 700e2000.thermal-sensor: throttrip: will throttle when cpu reaches 102500 mC
[ 12.471041] tegra_soctherm 700e2000.thermal-sensor: thermtrip: will shut down when gpu reaches 103000 mC
[ 12.482852] tegra_soctherm 700e2000.thermal-sensor: programming throttle for gpu to 103000
[ 12.482860] tegra_soctherm 700e2000.thermal-sensor: throttrip: will throttle when gpu reaches 103000 mC
[ 12.485357] tegra_soctherm 700e2000.thermal-sensor: thermtrip: will shut down when pll reaches 103000 mC
[ 12.501774] tegra_soctherm 700e2000.thermal-sensor: thermtrip: will shut down when mem reaches 103000 mC

and after these changes, it turns into:

[ 12.447113] tegra_soctherm 700e2000.thermal-sensor: missing thermtrips, will use critical trips as shut down temp
[ 12.472300] tegra_soctherm 700e2000.thermal-sensor: thermtrip: will shut down when cpu reaches 102500 mC
[ 12.481789] tegra_soctherm 700e2000.thermal-sensor: programming throttle for cpu to 102500
[ 12.495447] tegra_soctherm 700e2000.thermal-sensor: throttrip: will throttle when cpu reaches 102500 mC
[ 12.496514] tegra_soctherm 700e2000.thermal-sensor: thermtrip: will shut down when gpu reaches 103000 mC
[ 12.510353] tegra_soctherm 700e2000.thermal-sensor: programming throttle for gpu to 103000
[ 12.526856] tegra_soctherm 700e2000.thermal-sensor: throttrip: will throttle when gpu reaches 103000 mC
[ 12.528774] tegra_soctherm 700e2000.thermal-sensor: thermtrip: will shut down when pll reaches 103000 mC
[ 12.569352] tegra_soctherm 700e2000.thermal-sensor: programming throttle for pll to 103000
[ 12.577635] tegra_soctherm 700e2000.thermal-sensor: throttrip: will throttle when pll reaches 103000 mC
[ 12.590952] tegra_soctherm 700e2000.thermal-sensor: thermtrip: will shut down when mem reaches 103000 mC
[ 12.600783] tegra_soctherm 700e2000.thermal-sensor: programming throttle for mem to 103000
[ 12.609204] tegra_soctherm 700e2000.thermal-sensor: throttrip: will throttle when mem reaches 103000 mC

The "programming throttle ..." messages are something I've added locally
to trace what gets called. So it looks like for "pll" and "mem" thermal
zones, we now program trip points whereas we previously didn't.

The DT descriptioni (tegra210.dtsi) says one thing and the implementation says
something else.

If we refer to the PLL description, there is one 'hot' trip point and
one 'critical' trip point. No polling delay at all, so we need the
interrupts.

Logically, we should set the 'hot' trip point first, when the trip
point is crossed, we setup the next trip point, which is the critical.

With these two trip points, the first one will send a notification to
the userspace and the second one will force a shutdown of the
system. For both, no cooling device is expected.

I think the intention here is to use the soctherm's built-in throttling
mechanism as a last resort measure to try and cool the system down. I
suppose that could count as "passive" cooling, so specifying it as the
cooling device for the "passive" trip point may be more appropriate.

The throttling that happens here is quite severe, so we don't want it to
happen too early. I would expect that our "passive" trip point shouldn't
be a lot less than the "hot" temperature. I suspect that's the reason
why the "hot" trip point was reused for this.

I'm also beginning to think that we should just not expose the soctherm
throttling as a cooling device and instead keep it internal to the
soctherm driver entirely.

Well, actually I don't get the logic of the soctherm driver. It should
just rely on the thermal framework to set the trip point regardless
the cooling devices.

Again, "throttrip" doesn't map well to the concept of trip points
because its not a mechanism to notify when a certain temperature is
reached. It's an additional mechanism to automatically start throttling
once a given temperature threshold is crossed. So it's basically an
auto-cooling-device. If we program it only in response to a trip point
notification, there aren't any benefits to this throttle mechanism. So
again, I think we're probably better off just removing the cooling
device implementation for it and always program it with the "hot" or
"passive" trip point temperatures.

The device tree also is strange. For example, the dram sets
cooling-device = <&emc 0 0>; an inoperative action for a 'nominal'
trip point ... If the goal is to stop the mitigation, that is already
done by the governor when the trip point is crossed the way down. The
second trip point is an 'active' cooling device but it refers to a emc
which is, at the first glance, a passive cooling device.

I think this is because for the mem-thermal zone, "passive" is
considered to be less "severe" than "active". My understanding is that
the severity goes "active", "passive", "hot", "critical". "Active" trip
points are those where we want to use active cooling devices (such as a
fan, for example) to try and cool the device. The "passive" trip points
should only be reached when active cooling devices aren't up to the job
and passive mechanisms need to be deployed. Passive in this case meaning
the hardware itself has to be throttled.

If you look at the temperatures defined for passive vs. active for the
"mem" thermal zone, then clearly they are reversed. <&emc 0 0> should be
used for active trip points, and <&emc 1 1> means throttling of the EMC
frequency, i.e. for passive trip points.

The gpu description only describes hot and critical trip points. The
cooling device maps to the 'hot' trip point ! The governor is not used
in this case, so the cooling device is inoperative. Same for the cpu
thermal zone.

IOW, the driver is not correctly implemented and the device tree is
wrong. Thermal is not working correctly on these board AFAICT.

I'll try to rework this. As I mentioned above I think we can just remove
that throttle_heavy cooling device and instead hard-code that in the
driver to a given temperature. Given that this is probably all defunct
anyway, the best would probably be to extend the soctherm's
throttle-cfgs node with a temperature field so we can avoid the reliance
on trip points (which would allow us to get rid of the calls to the
get_thermal_instance() helper).

On the DT side, I think most of the cooling maps can be cleaned up. We
can remove the entries for "critical" and "hot" trip points if the
driver unconditionally programs the automated throttling. For EMC we
want to reverse the "passive" and "active" trip points and possibly drop
the dram-passive cooling map as well, since you mentioned the core would
take care of disabling the cooling device automatically.

Thierry

--