Re: [PATCH RFT v2 08/14] clk: qcom: smd-rpm: Separate out a macro for defining an AO clock

From: Dmitry Baryshkov
Date: Wed Mar 08 2023 - 19:51:13 EST


On 08/03/2023 23:35, Konrad Dybcio wrote:
To declare a keepalive variant of a bus clock, it will be useful to
have a reusable macro which will ease defining a keepalive variant
of an AO clock with an IS_CRITICAL flag. Introduce it.

Signed-off-by: Konrad Dybcio <konrad.dybcio@xxxxxxxxxx>
---
drivers/clk/qcom/clk-smd-rpm.c | 5 +++++
1 file changed, 5 insertions(+)

Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx>

--
With best wishes
Dmitry