[PATCH v2 6/6] md/raid10: fix memleak of md thread
From: Yu Kuai
Date: Fri Mar 10 2023 - 02:40:50 EST
From: Yu Kuai <yukuai3@xxxxxxxxxx>
In raid10_run(), if setup_conf() succeed and raid10_run() failed before
setting 'mddev->thread', then in the error path 'conf->thread' is not
freed.
Fix the problem by setting 'mddev->thread' right after setup_conf().
Fixes: 43a521238aca ("md-cluster: choose correct label when clustered layout is not supported")
Signed-off-by: Yu Kuai <yukuai3@xxxxxxxxxx>
---
drivers/md/raid10.c | 6 +++---
1 file changed, 3 insertions(+), 3 deletions(-)
diff --git a/drivers/md/raid10.c b/drivers/md/raid10.c
index bdfa02e8fe7e..2f1522bba80d 100644
--- a/drivers/md/raid10.c
+++ b/drivers/md/raid10.c
@@ -4142,6 +4142,9 @@ static int raid10_run(struct mddev *mddev)
if (!conf)
goto out;
+ mddev->thread = conf->thread;
+ conf->thread = NULL;
+
if (mddev_is_clustered(conf->mddev)) {
int fc, fo;
@@ -4154,9 +4157,6 @@ static int raid10_run(struct mddev *mddev)
}
}
- mddev->thread = conf->thread;
- conf->thread = NULL;
-
if (mddev->queue) {
blk_queue_max_write_zeroes_sectors(mddev->queue, 0);
blk_queue_io_min(mddev->queue, mddev->chunk_sectors << 9);
--
2.31.1