[PATCH v3 3/3] i2c: mpc: Use i2c-scl-clk-low-timeout-ms i2c property
From: Andi Shyti
Date: Sun Mar 12 2023 - 19:37:03 EST
"fsl,timeout" is marked as deprecated and replaced by the
"i2c-scl-clk-low-timeout-ms" i2c property.
Use this latter and, in case it is missing, for back
compatibility, check whether we still have "fsl,timeout" defined.
Signed-off-by: Andi Shyti <andi.shyti@xxxxxxxxxx>
Reviewed-by: Chris Packham <chris.packham@xxxxxxxxxxxxxxxxxxx>
---
drivers/i2c/busses/i2c-mpc.c | 12 +++++++++++-
1 file changed, 11 insertions(+), 1 deletion(-)
diff --git a/drivers/i2c/busses/i2c-mpc.c b/drivers/i2c/busses/i2c-mpc.c
index 87e5c1725750..28f11e30ac50 100644
--- a/drivers/i2c/busses/i2c-mpc.c
+++ b/drivers/i2c/busses/i2c-mpc.c
@@ -843,8 +843,18 @@ static int fsl_i2c_probe(struct platform_device *op)
mpc_i2c_setup_8xxx(op->dev.of_node, i2c, clock);
}
+ /*
+ * "fsl,timeout" has been marked as deprecated and, to maintain
+ * backward compatibility, we will only look for it if
+ * "i2c-scl-clk-low-timeout-ms" is not present.
+ */
result = of_property_read_u32(op->dev.of_node,
- "fsl,timeout", &mpc_ops.timeout);
+ "i2c-scl-clk-low-timeout-ms",
+ &mpc_ops.timeout);
+ if (result == -EINVAL)
+ result = of_property_read_u32(op->dev.of_node,
+ "fsl,timeout", &mpc_ops.timeout);
+
if (!result) {
mpc_ops.timeout *= HZ / 1000000;
if (mpc_ops.timeout < 5)
--
2.39.2