power-supply properties are reported in µV, µA and µW.
The IIO API provides mV, mA, mW, so the values need to
be multiplied by 1000.
Signed-off-by: Sebastian Reichel <sre@xxxxxxxxxx>
---
drivers/power/supply/generic-adc-battery.c | 3 +++
1 file changed, 3 insertions(+)
diff --git a/drivers/power/supply/generic-adc-battery.c b/drivers/power/supply/generic-adc-battery.c
index 917bd2a6cc52..535972a332b3 100644
--- a/drivers/power/supply/generic-adc-battery.c
+++ b/drivers/power/supply/generic-adc-battery.c
@@ -136,6 +136,9 @@ static int read_channel(struct gab *adc_bat, enum power_supply_property psp,
result);
if (ret < 0)
pr_err("read channel error\n");
+ else
+ *result *= 1000;
+
return ret;
}