[PATCH v2 0/5] Process connector bug fixes & enhancements

From: Anjali Kulkarni
Date: Tue Mar 14 2023 - 22:20:03 EST


From: Anjali Kulkarni <anjali.k.kulkarni@xxxxxxxxxx>

In this series, we add filtering to the proc connector module. This
is required to fix some bugs and also will enable the addition of event
based filtering, which will improve performance for anyone interested
in a subset of process events, as compared to the current approach,
which is to send all event notifications.

Thus, a client can register to listen for only exit or fork or a mix or
all of the events. This greatly enhances performance - currently, we
need to listen to all events, and there are 9 different types of events.
For eg. handling 3 types of events - 8K-forks + 8K-exits + 8K-execs takes
200ms, whereas handling 2 types - 8K-forks + 8K-exits takes about 150ms,
and handling just one type - 8K exits takes about 70ms.

Reason why we need the above changes and also a new event type
PROC_EVENT_NONZERO_EXIT, which is only sent by kernel to a listening
application when any process exiting has a non-zero exit status is:

Oracle DB runs on a large scale with 100000s of short lived processes,
starting up and exiting quickly. A process monitoring DB daemon which
tracks and cleans up after processes that have died without a proper exit
needs notifications only when a process died with a non-zero exit code
(which should be rare).

This change will give Oracle DB substantial performance savings - it takes
50ms to scan about 8K PIDs in /proc, about 500ms for 100K PIDs. DB does
this check every 3 secs, so over an hour we save 10secs for 100K PIDs.

Measuring the time using pidfds for monitoring 8K process exits took 4
times longer - 200ms, as compared to 70ms using only exit notifications
of proc connector. Hence, we cannot use pidfd for our use case.

This kind of a new event could also be useful to other applications like
Google's lmkd daemon, which needs a killed process's exit notification.

This patch series is organized as follows -

Patch 1 : Is needed for patches 2 & 3 to work.
Patch 2 : Fixes some bugs in proc connector, details in the patch.
Patch 3 : Test code for proc connector.
Patch 4 : Adds event based filtering for performance enhancements.
Patch 5 : Allow non-root users access to proc connector events.

v1->v2 changes:
- Fix comments by Jakub Kicinski to keep layering within netlink and
update kdocs.
- Move non-root users access patch last in series so remaining patches
can go in first.

Anjali Kulkarni (5):
netlink: Reverse the patch which removed filtering
connector/cn_proc: Add filtering to fix some bugs
connector/cn_proc: Test code for proc connector
connector/cn_proc: Performance improvements
connector/cn_proc: Allow non-root users access

drivers/connector/cn_proc.c | 103 +++++++++--
drivers/connector/connector.c | 22 ++-
drivers/w1/w1_netlink.c | 6 +-
include/linux/connector.h | 8 +-
include/linux/netlink.h | 6 +
include/uapi/linux/cn_proc.h | 62 +++++--
net/netlink/af_netlink.c | 35 +++-
net/netlink/af_netlink.h | 4 +
samples/connector/proc_filter.c | 301 ++++++++++++++++++++++++++++++++
9 files changed, 503 insertions(+), 44 deletions(-)
create mode 100644 samples/connector/proc_filter.c

--
2.39.2