Re: [PATCH 1/3] dt-bindings: iio: pressure: Support Honeywell mpr sensors

From: Krzysztof Kozlowski
Date: Sat Apr 01 2023 - 05:42:25 EST


On 01/04/2023 11:09, Andreas Klinger wrote:
> Honeywell mpr is a pressure sensor family. There are many different
> types with different pressure ranges. The range needs to be set up in
> the dt. Therefore new properties honeywell,pmin and honeywell,pmax are
> introduced.
>
> Add dt-bindings.
>
> Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx>
> ---
> .../bindings/iio/pressure/honeywell,mpr.yaml | 74 +++++++++++++++++++
> 1 file changed, 74 insertions(+)
> create mode 100644 Documentation/devicetree/bindings/iio/pressure/honeywell,mpr.yaml
>
> diff --git a/Documentation/devicetree/bindings/iio/pressure/honeywell,mpr.yaml b/Documentation/devicetree/bindings/iio/pressure/honeywell,mpr.yaml
> new file mode 100644
> index 000000000000..d6fad6f841cf
> --- /dev/null
> +++ b/Documentation/devicetree/bindings/iio/pressure/honeywell,mpr.yaml
> @@ -0,0 +1,74 @@
> +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
> +%YAML 1.2
> +---
> +$id: http://devicetree.org/schemas/iio/pressure/honeywell,mpr.yaml#
> +$schema: http://devicetree.org/meta-schemas/core.yaml#
> +
> +title: Honeywell mpr pressure sensor
> +
> +maintainers:
> + - Andreas Klinger <ak@xxxxxxxxxxxxx>
> +
> +description: |
> + Honeywell pressure sensor of type mpr. This sensor has an I2C and SPI interface. Only the I2C

Doesn't look wrapped according to Linux coding style (see Coding style).

> + interface is implemented.
> +
> + There are many subtypes with different pressure ranges available. Therefore the minimum and
> + maximum pressure values of the specific sensor needs to be specified in Pascal.
> +
> + Specifications about the devices can be found at:
> + https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/ \
> + pressure-sensors/board-mount-pressure-sensors/micropressure-mpr-series/documents/ \
> + sps-siot-mpr-series-datasheet-32332628-ciid-172626.pdf

Lines are not continued, so drop \

> +
> +properties:
> + compatible:
> + const: honeywell,mpr

You need device specific compatible, not some generic one. Rename also
then the filename (should match the compatible).

> +
> + reg:
> + maxItems: 1
> +
> + interrupts:
> + maxItems: 1
> +
> + reset-gpios:
> + description:
> + Optional GPIO for resetting the device. If not present the device is not resetted.

Are you sure it is wrapped properly?

> + maxItems: 1
> +
> + honeywell,pmin:
> + description:
> + Minimum pressure value the sensor can measure in pascal.

Use standard unit suffix:
https://github.com/devicetree-org/dt-schema/blob/main/dtschema/schemas/property-units.yaml

> + $ref: /schemas/types.yaml#/definitions/uint32
> +
> + honeywell,pmax:
> + description:
> + Maximum pressure value the sensor can measure in pascal.
> + $ref: /schemas/types.yaml#/definitions/uint32

Same.

Why these values are suitable for DT? Does it depend on type of sensor
(thus it is implied from compatible) or on system setup?

> +
> +required:
> + - compatible
> + - reg
> + - honeywell,pmin
> + - honeywell,pmax
> +


Best regards,