Re: [PATCH V2] clk: imx: imx6sx: spdif clock rate is too high for asrc

From: Ahmad Fatoum
Date: Mon Apr 03 2023 - 04:34:34 EST


Hello Peng,

On 03.04.23 10:21, Peng Fan (OSS) wrote:
> From: Shengjiu Wang <shengjiu.wang@xxxxxxx>
>
> spdif clock is one of the asrc clock source, which is used
> for ideal ratio mode. when set to 98.304MHz, it cause the
> divider of asrc input clock and output clock exceed the
> maximum value, and asrc driver saturate the value to maximum
> value, which will cause the ASRC's performance very bad.
> So we need to set spdif clock to a proper rate. which make asrc
> divider not exceed maximum value, at least one of divider not
> exceed maximum value.
> The target is spdif clock rate / output(or input) sample rate
> less than 1024(which is maximum divider).
>
> Fixes: f1541e15e38e ("clk: imx6sx: Switch to clk_hw based API")

Before referenced commit, it looked like this:

clk_set_rate(clks[IMX6SX_CLK_SPDIF_PODF], 98304000);

I think commit d55135689019 ("ARM: imx: add clock driver for imx6sx")
is what you're after.

Cheers,
Ahmad

> Signed-off-by: Shengjiu Wang <shengjiu.wang@xxxxxxx>
> Signed-off-by: Peng Fan <peng.fan@xxxxxxx>
> ---
>
> V2:
> Add Fixes tag
>
> drivers/clk/imx/clk-imx6sx.c | 2 +-
> 1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/drivers/clk/imx/clk-imx6sx.c b/drivers/clk/imx/clk-imx6sx.c
> index 7cf86707bc39..3face052527d 100644
> --- a/drivers/clk/imx/clk-imx6sx.c
> +++ b/drivers/clk/imx/clk-imx6sx.c
> @@ -520,7 +520,7 @@ static void __init imx6sx_clocks_init(struct device_node *ccm_node)
> clk_set_rate(hws[IMX6SX_CLK_PLL4_AUDIO_DIV]->clk, 393216000);
>
> clk_set_parent(hws[IMX6SX_CLK_SPDIF_SEL]->clk, hws[IMX6SX_CLK_PLL4_AUDIO_DIV]->clk);
> - clk_set_rate(hws[IMX6SX_CLK_SPDIF_PODF]->clk, 98304000);
> + clk_set_rate(hws[IMX6SX_CLK_SPDIF_PODF]->clk, 24576000);
>
> clk_set_parent(hws[IMX6SX_CLK_AUDIO_SEL]->clk, hws[IMX6SX_CLK_PLL3_USB_OTG]->clk);
> clk_set_rate(hws[IMX6SX_CLK_AUDIO_PODF]->clk, 24000000);

--
Pengutronix e.K. | |