On Tue, Apr 04, 2023 at 10:12:02AM -0400, William Breathitt Gray wrote:
> ADC sample captures take a certain amount of time to complete after
> initiated; this conversion time range can be anywhere from 5 uSec to
> 53.68 Seconds depending on the configuration of the Analog Input Frame
> Timer register. When the conversion is in progress, the ADC Status
> register CNV bit is high. Utilize regmap_read_poll_timeout() to poll
> until the ADC conversion is completed (or timeout if more than 53.68
> Seconds passes).

...

> /* trigger ADC sample capture by writing to the 8-bit

Perhaps fix the style here while at it?

/*
* Trigger ADC sample capture by writing to the 8-bit

> * Software Strobe Register and wait for completion
> + * Range is 5 uSec to 53.68 Seconds in steps of 25 nanoseconds.

seconds (in SI the small letter is for the unit(s) of seconds).

Same for the commit message.

> + * The actual Analog Input Frame Timer time interval is calculated as:
> + * ai_time_frame_ns = ( AIFT + 1 ) * ( 25 nSec ).

nSec --> nanosecond

> + * Where 0 <= AIFT <= 2147483648.
> */

--
With Best Regards,
Andy Shevchenko