Re: [PATCH v2 2/3] hwmon: (pmbus/core): Add regulator event support

From: Mark Brown
Date: Tue Apr 11 2023 - 08:08:30 EST


On Mon, Apr 10, 2023 at 11:19:41AM +0300, Matti Vaittinen wrote:
> to 6. huhtik. 2023 klo 16.43 Mark Brown (broonie@xxxxxxxxxx) kirjoitti:

> > I'm not sure what you're expecting there? A device working with itself
> > shouldn't disrupt any other users.

> I have no concrete idea, just a vague uneasy feeling knowing that
> devices tend to interact with each other. I guess it is more about the
> amount of uncertainty caused by my lack of knowledge regarding what
> could be done by these handlers. So, as I already said - if no one
> else is bothered by this then I definitely don't want to block the
> series. Still, if the error handling should be kept internal to PMBus
> - then we should probably either say that consumer drivers must not
> (forcibly) turn off the supply when receiving these notifications - or
> not send these notifications from PMBus and allow PMBus to decide
> error handling internally. (Again, I don't know if any in-tree
> consumer drivers do turn off the supply regulator in error handlers -
> but I don't think it is actually forbidden). Or am I just making a
> problem that does not exist?

I think you are making a problem that doesn't exist.

> > Like I say I'm not sure how much practical difference it makes to think
> > too hard about differentiating the errors.

> I would do at least two classes.

> 1) critical class - it is Ok for the consumer to forcibly shut down
> the regulator, or maybe the whole system.
> 2) warning class - it is not Ok to forcibly shut down the regulator.

How severe an issue bad power is will be partly determined by what the
consumer is doing with the power, it's going to be in a fairly narrow
range but there is a range.

Attachment: signature.asc