[PATCH 2/3] iio: gts: fix units of available integration times
From: Matti Vaittinen
Date: Wed Apr 12 2023 - 08:28:50 EST
The available integration times should be in the units of seconds, not
micro seconds.
Use the new IIO_VAL_INT_MICRO to return times in seconds
Signed-off-by: Matti Vaittinen <mazziesaccount@xxxxxxxxx>
---
drivers/iio/industrialio-gts-helper.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/iio/industrialio-gts-helper.c b/drivers/iio/industrialio-gts-helper.c
index 8bb68975b259..e242d0eb8b94 100644
--- a/drivers/iio/industrialio-gts-helper.c
+++ b/drivers/iio/industrialio-gts-helper.c
@@ -683,7 +683,7 @@ int iio_gts_avail_times(struct iio_gts *gts, const int **vals, int *type,
return -EINVAL;
*vals = gts->avail_time_tables;
- *type = IIO_VAL_INT;
+ *type = IIO_VAL_INT_MICRO;
*length = gts->num_avail_time_tables;
return IIO_AVAIL_LIST;
--
2.39.2
--
Matti Vaittinen, Linux device drivers
ROHM Semiconductors, Finland SWDC
Kiviharjunlenkki 1E
90220 OULU
FINLAND
~~~ "I don't think so," said Rene Descartes. Just then he vanished ~~~
Simon says - in Latin please.
~~~ "non cogito me" dixit Rene Descarte, deinde evanescavit ~~~
Thanks to Simon Glass for the translation =]