Re: [PATCH 0/3] KVM: x86: SGX vs. XCR0 cleanups

From: Sean Christopherson
Date: Thu Apr 13 2023 - 18:48:09 EST


On Thu, Apr 13, 2023, Kai Huang wrote:
> On Wed, 2023-04-12 at 08:22 -0700, Sean Christopherson wrote:
> > KVM's uAPI for initiating TDH.MNG.INIT could obviously filter out
> > unsupported leafs, but doing so would lead to potential ABI breaks, e.g. if a leaf
> > that KVM filters out becomes known to the TDX Module, then upgrading the TDX Module
> > could result in previously allowed input becoming invalid.
>
> How about only filtering out PV related CPUIDs when applying CPUIDs to
> TDH.MNG.INIT? I think we can assume they are not gonna be known to TDX module
> anyway.

Nope, not going down that road. Fool me once[*], shame on you. Fool me twice,
shame on me :-)

Objections to hardware vendors defining PV interfaces aside, there exist leafs
that are neither PV related nor known to the TDX module, e.g. Centaur leafs. I
think it's extremely unlikely (understatement) that anyone will want to expose
Centaur leafs to a TDX guest, but again I want to say out of the business of
telling userspace what is and isn't sane CPUID models.

[*] https://lore.kernel.org/all/20221210160046.2608762-6-chen.zhang@xxxxxxxxx

> > Even if that weren't the case, ignoring KVM_SET_CPUID{2} would be a bad option
> > becuase it doesn't allow KVM to open behavior in the future, i.e. ignoring the
> > leaf would effectively make _everything_ valid input. If KVM were to rely solely
> > on TDH.MNG.INIT, then KVM would want to completely disallow KVM_SET_CPUID{2}.
>
> Right. Disallowing SET_CPUID{2} probably is better, as it gives userspace a
> more concrete result.
>
> >
> > Back to Zhi's question, the best thing to do for TDX and SNP is likely to require
> > that overlap between KVM_SET_CPUID{2} and the "trusted" CPUID be consistent. The
> > key difference is that KVM would be enforcing consistency, not sanity. I.e. KVM
> > isn't making arbitrary decisions on what is/isn't sane, KVM is simply requiring
> > that userspace provide a CPUID model that's consistent with what userspace provided
> > earlier.
>
> So IIUC, you prefer to verifying the CPUIDs in SET_CPUID{2} are a super set of
> the CPUIDs provided in TDH.MNG.INIT? And KVM manually verifies all CPUIDs for
> all vcpus are consistent (the same) in SET_CPUID{2}?

Yes, except KVM doesn't need to verify vCPUs are consistent with respect to each
other, just that each vCPU is consistent with respect to what was reported to the
TDX Module.

> Looks this is over-complicated, _if_ the "only filtering out PV related CPUIDs
> when applying CPUIDs to TDH.MNG.INIT" approach works.

It's not complicated at all. Walk through the leafs defined during TDH.MNG.INIT,
reject KVM_SET_CPUID if a leaf isn't present or doesn't match exactly. Or has
the TDX spec changed and it's no longer that simple?